Terasaki 000935 Shunt Trip 24V DC, for TemBreak 2 MCCBs up to 400A
- Brand:
- Terasaki
- Part number:
- 000935
Shunt trip with a 24 V DC coil for tripping TemBreak 2 MCCBs on the 160 A, 250 A and 400 A frames from PLC, BMS or relay outputs. Terasaki part number 000935.
- 24 V DC coil for PLC, BMS and safety relay outputs
- No interposing relay needed
- Fits TemBreak 2 160 A, 250 A and 400 A frames
- Shunt trip or UVR per breaker, not both
Available to order
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 3-5 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Coil voltage | 24 V DC |
|---|
Fit
| Fits device | Terasaki S160-NF, Terasaki S160-NJ, Terasaki S160-GJ, Terasaki S250-NJ, Terasaki S250-GJ, Terasaki S250-NE, Terasaki S250-GE, Terasaki S400-NN, Terasaki S400-NJ, Terasaki S400-NE |
|---|---|
| Fits MCCB frame | 160 A, 250 A, 400 A |
| Panelboard range | Resilience Standard, Resilience PlusWhat does this mean?Incomer and outgoing ways in one wall-mounted board. 250 A or 400 A busbars, 4 to 18 outgoing ways, outgoing MCCBs up to 125 A, Form 3b Type 2, doors included. Modular: a separate incomer housing beside the panel board, with add-on enclosures and cableways. 400 A or 800 A busbars, 6 to 18 outgoing ways, outgoing MCCBs up to 250 A (400 A on the twin board), Form 3a or 3b Type 2, doors optional. |
Identification
| Brand | Terasaki |
|---|---|
| Part number | 000935 |
| Range | Terasaki TemBreak2 |
| Type | Shunt trip |
More technical data
| Type | shunt trip, internal |
|---|---|
| Coil | 24 V DC |
| Trigger | voltage applied to the coil |
| Breaker frames | 160 A, 250 A and 400 A TemBreak 2 |
| Not with | an under-voltage release in the same breaker |
| Supplied | one unit with fitting instructions |
Product details
The Terasaki 000935 shunt trip has a 24 V DC coil, the control voltage used by many PLCs, BMS controllers and safety relays. Fitted in a TemBreak 2 MCCB on the 160 A, 250 A or 400 A frame, it trips the breaker on a command from those systems, with no interposing relay needed to change voltage.
Key features
- 24 V DC coil to suit common control system voltages
- Trips the breaker when a PLC output, relay contact or pushbutton energises the coil
- Internal accessory in the trip-coil position, fitted after the front cover clips are lifted
- Uses the position shared with the under-voltage release: one per breaker
- Terminations on the accessory itself or on an optional terminal block clipped to the breaker
Typical applications
Automated shutdown of distribution circuits from a PLC or BMS, 24 V DC fire alarm interface outputs, emergency stop systems built on 24 V safety relays, and load shedding when a generator is carrying the site. A shunt trip needs power to act, so where the breaker must trip if the 24 V supply fails, specify an under-voltage release instead.
Compatible TemBreak 2 devices: S160-NF, S160-NJ and S160-GJ; S250-NJ, S250-GJ, S250-NE and S250-GE; S400-NJ, S400-NE and the S400-NN switch-disconnector, including those in Resilience panel boards.
Add it to your cart, or ask us to check the coil voltage against your control system.