Terasaki 000904 Shunt Trip 100-120V AC, for TemBreak 2 MCCBs up to 400A
- Brand:
- Terasaki
- Part number:
- 000904
Shunt trip with a 100-120 V AC coil for remote tripping of TemBreak 2 MCCBs on the 160 A, 250 A and 400 A frames. Terasaki part number 000904.
- 100-120 V AC coil for 110 V control circuits
- Remote tripping of TemBreak 2 MCCBs
- 160 A, 250 A and 400 A frames
- Shunt trip or UVR per breaker, not both
Available to order
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 3-5 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Coil voltage | 100-120 V AC |
|---|
Fit
| Fits device | Terasaki S160-NF, Terasaki S160-NJ, Terasaki S160-GJ, Terasaki S250-NJ, Terasaki S250-GJ, Terasaki S250-NE, Terasaki S250-GE, Terasaki S400-NN, Terasaki S400-NJ, Terasaki S400-NE |
|---|---|
| Fits MCCB frame | 160 A, 250 A, 400 A |
| Panelboard range | Resilience Standard, Resilience PlusWhat does this mean?Incomer and outgoing ways in one wall-mounted board. 250 A or 400 A busbars, 4 to 18 outgoing ways, outgoing MCCBs up to 125 A, Form 3b Type 2, doors included. Modular: a separate incomer housing beside the panel board, with add-on enclosures and cableways. 400 A or 800 A busbars, 6 to 18 outgoing ways, outgoing MCCBs up to 250 A (400 A on the twin board), Form 3a or 3b Type 2, doors optional. |
Identification
| Brand | Terasaki |
|---|---|
| Part number | 000904 |
| Range | Terasaki TemBreak2 |
| Type | Shunt trip |
More technical data
| Type | shunt trip, internal |
|---|---|
| Coil | 100-120 V AC |
| Action | trips the breaker when the coil is energised |
| Breaker frames | 160 A, 250 A and 400 A TemBreak 2 |
| Not with | an under-voltage release in the same breaker |
| Supplied | one shunt trip, individually packed with fitting instructions |
Product details
The Terasaki 000904 shunt trip lets you trip a TemBreak 2 MCCB from a distance. Its coil is rated 100-120 V AC, the band to pick when the trip circuit runs from a 110 V or 120 V AC control supply such as the secondary of a control transformer. Energise the coil and the breaker trips.
Key features
- Coil voltage 100-120 V AC, matched to 110 V and 120 V AC control circuits
- Trips the breaker as soon as a remote contact or pushbutton puts voltage on the coil
- Fits inside the breaker in the trip-coil position and clicks into place once the front cover clips are released with a screwdriver
- Uses the same position as the under-voltage release, so a breaker takes one or the other
- Control wiring goes to its own screw terminals, or to an optional terminal block clipped to the breaker side
Typical applications
Remote emergency switching from stop buttons in 110 V AC control schemes, trip commands from protection or earth-fault relays, and shutting down plant on a signal from a fire alarm interface or BMS. A shunt trip can only act while its control supply is healthy; where the breaker must open if that supply is lost, the fail-safe choice is an under-voltage release.
Fits TemBreak 2 S160-NF, S160-NJ, S160-GJ, S250-NJ, S250-GJ, S250-NE, S250-GE, S400-NJ and S400-NE MCCBs and the S400-NN switch-disconnector, as used in Resilience Standard and Resilience Plus panel boards. Shunt trips for other AC and DC control voltages are listed separately.
Add it to your cart, or ask us if you are not sure which coil voltage your control circuit needs.