Terasaki 003448 Shunt Trip 24V DC, for TemBreak 2 Lite 160A and 250A Frames

Brand:
Terasaki
Part number:
003448

24 V DC shunt trip for TemBreak 2 Lite 160 A and 250 A frame breakers, for remote tripping from PLC, BMS or alarm system outputs. Terasaki part number 003448.

  • 24V DC coil, 18-30V DC operating range
  • Trips from PLC, BMS or fire alarm outputs
  • 0.03 A peak exciting current
  • Fits 160A and 250A Lite frames
£84.29 ex VAT£101.15 inc VAT

Available to order

Datasheet (PDF)Opens in a new tabBuild a board with this partConfigure a complete Terasaki Resilience panel board online: incomer, outgoing MCCBs, surge and metering, with a drawing and parts list.

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 3-5 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

Coil voltage24 V DC

Fit

Fits deviceTerasaki E160-SF, Terasaki S160-SCJ, Terasaki E250-SJ, Terasaki S250-SN, Terasaki S250-SJ
Fits MCCB frame160 A, 250 A
Panelboard rangeResilience Standard, Resilience Plus
What does this mean?

Incomer and outgoing ways in one wall-mounted board. 250 A or 400 A busbars, 4 to 18 outgoing ways, outgoing MCCBs up to 125 A, Form 3b Type 2, doors included. Modular: a separate incomer housing beside the panel board, with add-on enclosures and cableways. 400 A or 800 A busbars, 6 to 18 outgoing ways, outgoing MCCBs up to 250 A (400 A on the twin board), Form 3a or 3b Type 2, doors optional.

Identification

BrandTerasaki
Part number003448
RangeTerasaki TemBreak2 Lite
TypeShunt trip

More technical data

Operating range18-30 V DC
Peak exciting current0.03 A
Coil terminalsC1, C2
Mountinginside the breaker, trip-coil position

Product details

The Terasaki 003448 is a 24 V DC shunt trip for TemBreak 2 Lite breakers on the 160 A and 250 A frames. 24 V DC is the usual control voltage of PLCs, safety relays and fire alarm interface modules, so this coil lets those systems trip the breaker directly or through a small interface relay.

Key features

  • 24 V DC coil with a permissible range of 18-30 V DC (75-125 % of rated)
  • 0.03 A peak exciting current
  • Rated for continuous energisation; there is no anti-burn switch
  • Main contacts usually start to open within 30 ms of rated voltage
  • Takes the breaker's one trip-coil position, so it cannot be combined with an under-voltage release

Typical applications

Automation and building services panels where a PLC output, a BMS controller or a fire alarm interface trips an outgoing way, and load shedding from an energy management system. Pair it with an alarm switch so the controller can see that the breaker has opened.

Suits the S160-SCJ (160 A frame) and E250-SJ, S250-SJ and S250-SN (250 A frame) from the TemBreak 2 Lite range we sell. Auxiliary and alarm switches fit alongside it.