Terasaki 003462 Shunt Trip 100-120V DC, for TemBreak 2 Lite 160A and 250A Frames
- Brand:
- Terasaki
- Part number:
- 003462
Shunt trip with a 100-120 V DC coil for TemBreak 2 Lite 160 A and 250 A frame breakers, for 110 V DC battery tripping supplies. Terasaki part number 003462.
- 100-120V DC coil for 110V DC batteries
- 0.011 A peak exciting current
- Continuously rated, no anti-burn switch
- Fits 160A and 250A Lite frames
Available to order
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 3-5 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Coil voltage | 100-120 V DC |
|---|
Fit
| Fits device | Terasaki E160-SF, Terasaki S160-SCJ, Terasaki E250-SJ, Terasaki S250-SN, Terasaki S250-SJ |
|---|---|
| Fits MCCB frame | 160 A, 250 A |
| Panelboard range | Resilience Standard, Resilience PlusWhat does this mean?Incomer and outgoing ways in one wall-mounted board. 250 A or 400 A busbars, 4 to 18 outgoing ways, outgoing MCCBs up to 125 A, Form 3b Type 2, doors included. Modular: a separate incomer housing beside the panel board, with add-on enclosures and cableways. 400 A or 800 A busbars, 6 to 18 outgoing ways, outgoing MCCBs up to 250 A (400 A on the twin board), Form 3a or 3b Type 2, doors optional. |
Identification
| Brand | Terasaki |
|---|---|
| Part number | 003462 |
| Range | Terasaki TemBreak2 Lite |
| Type | Shunt trip |
More technical data
| Permissible range | 75-125 % of rated voltage |
|---|---|
| Peak exciting current | 0.011 A |
| Coil terminals | C1, C2 |
| Mounting | internal accessory, trip-coil position |
Product details
The Terasaki 003462 is a shunt trip with a 100-120 V DC coil for TemBreak 2 Lite breakers on the 160 A and 250 A frames. It is meant for the 110 V DC battery supplies that often power protection and tripping in substations and large switchrooms, so low-voltage breakers can be tripped from the same battery as the rest of the protection scheme.
Key features
- Coil band 100-120 V DC, permissible from 75 % to 125 % of rated voltage
- Low current draw: 0.011 A peak exciting current
- No anti-burn switch; the coil is rated for continuous duty
- Breaker contacts usually start opening within 30 ms of rated voltage
- One trip-coil position per breaker, shared with the under-voltage release option
Typical applications
Intertripping from protection relays on a 110 V DC battery, tripping LV auxiliary supplies in substations, and remote trip circuits in plant where the DC system keeps control power available during a mains failure. Fit an alarm switch where the trip must be reported back to the SCADA or protection panel.
For the TemBreak 2 Lite S160-SCJ (160 A frame) and E250-SJ, S250-SJ and S250-SN (250 A frame) breakers in our range.