Terasaki 003431 Shunt Trip 380-450V AC, for TemBreak 2 Lite 160A and 250A Frames
- Brand:
- Terasaki
- Part number:
- 003431
Shunt trip with a 380-450 V AC coil for TemBreak 2 Lite 160 A and 250 A frame breakers, wired across two phases of a 400 V or 415 V supply. Terasaki part number 003431.
- 380-450V AC coil, phase-to-phase connection
- No neutral or control transformer needed
- 0.0065 A peak exciting current
- Fits 160A and 250A Lite frames
Available to order
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 3-5 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Coil voltage | 380-450 V AC |
|---|
Fit
| Fits device | Terasaki E160-SF, Terasaki S160-SCJ, Terasaki E250-SJ, Terasaki S250-SN, Terasaki S250-SJ |
|---|---|
| Fits MCCB frame | 160 A, 250 A |
| Panelboard range | Resilience Standard, Resilience PlusWhat does this mean?Incomer and outgoing ways in one wall-mounted board. 250 A or 400 A busbars, 4 to 18 outgoing ways, outgoing MCCBs up to 125 A, Form 3b Type 2, doors included. Modular: a separate incomer housing beside the panel board, with add-on enclosures and cableways. 400 A or 800 A busbars, 6 to 18 outgoing ways, outgoing MCCBs up to 250 A (400 A on the twin board), Form 3a or 3b Type 2, doors optional. |
Identification
| Brand | Terasaki |
|---|---|
| Part number | 003431 |
| Range | Terasaki TemBreak2 Lite |
| Type | Shunt trip |
More technical data
| Permissible voltage | 85-110 % of rated |
|---|---|
| Peak exciting current | 0.0065 A |
| Terminals | C1, C2 |
| Mounting | internal accessory, trip-coil position |
Product details
The Terasaki 003431 shunt trip has a 380-450 V AC coil, so a TemBreak 2 Lite breaker on the 160 A or 250 A frame can be tripped from a phase-to-phase voltage. Wired across two lines of a 400 V or 415 V supply, it needs no neutral and no control transformer.
Key features
- Coil rated 380-450 V AC for line-to-line connection
- Lowest coil current of the AC shunt trips: 0.0065 A peak
- Continuous-rated coil, no anti-burn switch
- Contacts generally begin to part within 30 ms of rated voltage reaching the coil
- One trip-coil position per breaker: fit this or an under-voltage release
Typical applications
Three-phase installations where no neutral is brought to the panel, such as motor, pump and compressor feeders, and boards where a 400 V tripping supply is simpler than adding a control transformer. Because a shunt trip only works with voltage present, take its supply from a point that stays live whenever a trip may be needed.
Fits the TemBreak 2 Lite S160-SCJ (160 A frame) together with the E250-SJ, S250-SJ and S250-SN (250 A frame). Auxiliary and alarm switches can share the breaker.