Type 2 SPDs for TN-C-S (PME) Supplies

Type 2 surge protective devices for TN-C-S (PME) supplies, the earthing arrangement most UK properties have.

Skip to products

16 productsshowing 1-16

Products

DEHNguard DG TT 2P 5 275 Compact Type 2 Surge Protection Device, 1 Module Single Phase TT/TN

DEHN · 900450

Single phase · TT, TN-S, TN-C-S (PME) · 1 module · Remote contact: No

£74.65 ex VAT£89.58 inc VAT

Checking stock...

DEHNguard DG S 275 Type 2 Surge Protection Device, 1 Module Single Phase TN-C-S

DEHN · 952070

Single phase · TN-C-S (PME) · 1 module · Remote contact: No

£72.28 ex VAT£86.74 inc VAT

Checking stock...

Type 2 Surge Protection Device with Remote Signalling, 1 Module Single Phase TN-C-S

DEHN · 952090

Single phase · TN-C-S (PME) · 1 module · Remote contact: Yes

£144.58 ex VAT£173.50 inc VAT

Checking stock...

Surge-Trap STPT2-40K275V-2PGM Type 2 Surge Protection Device, 2 Pole TT

Mersen · 83020117

Single phase · TT, TN-S, TN-C-S (PME) · 2 modules · Remote contact: Yes

£110.56 ex VAT£132.67 inc VAT

Checking stock...

Surge-Trap STPT2-40K275V-2PM Type 2 Surge Protection Device, 2 Pole TN-S

Mersen · 83020123

Single phase · TN-S, TN-C-S (PME) · 2 modules · Remote contact: Yes

£85.07 ex VAT£102.08 inc VAT

Checking stock...

DEHNguard DG TT 5 275 Compact Type 2 Surge Protection Device, 2 Module Three Phase TT/TN

DEHN · 900455

Three phase · TT, TN-S, TN-C-S (PME) · 2 modules · Remote contact: No

£139.92 ex VAT£167.90 inc VAT

Checking stock...

DEHNguard DG M TT 2P 275 Type 2 Surge Protection Device, 2 Module Single Phase TT/TN

DEHN · 952110

Single phase · TT, TN-S, TN-C-S (PME) · 2 modules · Remote contact: No

£139.95 ex VAT£167.94 inc VAT

Checking stock...

Type 2 Surge Protection Device with Remote Signalling, 2 Module Single Phase TT

DEHN · 952115

Single phase · TT, TN-S, TN-C-S (PME) · 2 modules · Remote contact: Yes

£179.27 ex VAT£215.12 inc VAT

Checking stock...

DEHNguard DG M TN 275 Type 2 Surge Protection Device, 2 Module Single Phase TN

DEHN · 952200

Single phase · TN-S, TN-C-S (PME) · 2 modules · Remote contact: No

£101.27 ex VAT£121.52 inc VAT

Checking stock...

Type 2 Surge Protection Device with Remote Signalling, 2 Module Single Phase TN

DEHN · 952205

Single phase · TN-S, TN-C-S (PME) · 2 modules · Remote contact: Yes

£210.95 ex VAT£253.14 inc VAT

Checking stock...

Surge-Trap STPT2-40K275V-4PGM Type 2 Surge Protection Device, 4 Pole TT

Mersen · 83020147

Three phase · TT, TN-S, TN-C-S (PME) · 4 modules · Remote contact: Yes

£221.74 ex VAT£266.09 inc VAT

Checking stock...

Surge-Trap STPT2-40K275V-4PM Type 2 Surge Protection Device, 4 Pole TN-S

Mersen · 83020153

Three phase · TN-S, TN-C-S (PME) · 4 modules · Remote contact: Yes

£174.40 ex VAT£209.28 inc VAT

Checking stock...

DEHNguard DG M TT 275 Type 2 Surge Protection Device, 4 Module Three Phase TT

DEHN · 952310

Three phase · TT, TN-S, TN-C-S (PME) · 4 modules · Remote contact: No

£380.60 ex VAT£456.72 inc VAT

Checking stock...

Type 2 Surge Protection Device with Remote Signalling, 4 Module Three Phase TT/TN

DEHN · 952315

Three phase · TT, TN-S, TN-C-S (PME) · 4 modules · Remote contact: Yes

£432.94 ex VAT£519.53 inc VAT

Checking stock...

Type 2 Surge Protection Device, 4 Module Three Phase TN

DEHN · 952400

Three phase · TN-S, TN-C-S (PME) · 4 modules · Remote contact: No

£203.00 ex VAT£243.60 inc VAT

Checking stock...

Type 2 Surge Protection Device with Remote Signalling, 4 Module Three Phase TN

DEHN · 952405

Three phase · TN-S, TN-C-S (PME) · 4 modules · Remote contact: Yes

£238.08 ex VAT£285.70 inc VAT

Checking stock...

Showing 16 of 16

Buying guide

Type 2 SPDs are fitted at distribution boards and consumer units to protect the installation from switching surges and the effects of nearby lightning. The device must suit the earthing system: on a TN-C-S (PME) supply the network's neutral and earth are combined in the supply cable and separated at the origin of the installation.

Choose single phase or three phase to match the board, and check whether you need a remote signalling contact.

Questions

How do I know the earthing system?
Check the supply and the installation certificate. TN-C-S (PME) has a combined neutral and earth from the network; TN-S has a separate earth, often the cable sheath; TT uses an earth electrode at the property.
Where does a Type 2 SPD go?
At the distribution board or consumer unit, as close to the origin of the installation as practical, with short connecting leads.
Do I also need a Type 1 device?
Where the building has a lightning protection system or an overhead line supply, a Type 1+2 device at the origin is usually required. Check BS 7671 for your installation.