Mersen Surge-Trap STPT2-40K275V-4PGM Type 2 Surge Protection Device, 4 Pole TT
- Brand:
- Mersen
- Part number:
- 83020147
- EAN:
- 8435297849230
Four-pole pluggable Type 2 surge arrester for three-phase TT systems at 230/400V, rated Imax 40kA per phase with a remote end-of-life contact.
- Type 2 protection for three-phase TT
- Imax 40kA, In 20kA, Up 1.3kV
- Remote end-of-life contact
- Plug-in coded cartridges
- Reversible cable entry
13 in stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Three phase |
|---|---|
| Earthing system | TT, TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TT/TN |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 2 |
|---|---|
| Nominal discharge current (In) | 20 kA |
| Max discharge current (Imax) | 40 kA |
| Voltage protection level (Up) | 1.3 kV |
Dimensions
| DIN rail width | 4 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | Mersen |
|---|---|
| Part number | 83020147 |
| EAN | 8435297849230 |
| Range | Mersen Surge-Trap STPT2 |
More technical data
| Manufacturer | Mersen (Surge-Trap STPT2, catalogue STPT2-40K275V-4PGM) |
|---|---|
| SPD class | Type 2 / Class II to IEC 61643-11 and EN 61643-11 |
| System | TT, three phase plus neutral; Un 230/400 VAC; Uc 275V |
| Max discharge current Imax (8/20) | 40kA; nominal discharge current In: 20kA |
| Voltage protection level Up at In | 1.3kV (L-N), 1.5kV (N-PE) |
| Remote contact | yes; cartridges SP2-40K275V (L-N) and SP2-40K-N (N-PE) |
- Response time 25ns; back-up fuse 125A gG; Icc 25kA
- IP20, PA66 CT1 V-0 body, -40 to +80C, reversible chassis
Product details
Three-phase TT boards need a neutral-to-earth element as well as line protection, and this four-pole Surge-Trap STPT2 provides both. Each phase is rated at 40kA maximum discharge current with the protection level held to 1.3kV, and the neutral path uses a dedicated 265V cartridge.
Key features
- Type 2 / Class II protection for three-phase TT distribution boards
- Three line cartridges plus a dedicated neutral-to-earth cartridge
- Imax of 40kA and In of 20kA per phase at a 1.3kV protection level
- Mechanically coded plug-in cartridges for error-free replacement
- Visual and remote end-of-life indicators, 25ns response time
Typical applications
Use it on three-phase supply distribution panels with an electrode earth: agricultural and horticultural installations, water and wastewater pumping, quarries and outdoor materials handling, telecoms and broadcast compounds, wind and solar balance-of-plant panels, and temporary site distribution.
Compliance
Tested to IEC 61643-11 and EN 61643-11 as a Type 2 / Class II device, with a PA66 CT1 V-0 body and IP20 protection for enclosure mounting. BS 7671 requires transient overvoltage risk to be assessed and coordinated protection provided where the consequences justify it.