DEHN Type 2 Surge Protection Device with Remote Signalling, 4 Module Three Phase TT/TN
- Brand:
- DEHN
- Part number:
- 952315
- EAN:
- 4013364108486
Four-module Type 2 surge arrester for three-phase TT and TN systems with monitoring contacts, so protection status can be reported to a BMS, SCADA or alarm panel.
- Type 2 protection, three-phase TT and TN
- Monitoring contacts for remote alarm
- Four DIN modules, pluggable
- Local status indication
7 in stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Three phase |
|---|---|
| Earthing system | TT, TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TT/TN |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 2 |
|---|
Dimensions
| DIN rail width | 4 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 952315 |
| EAN | 4013364108486 |
| Range | DEHNguard |
More technical data
| Earthing systems | three-phase TT and TN |
|---|---|
| Status signalling | local indication plus monitoring (remote signalling) contacts |
| Width | 4 DIN modules |
Product details
Three-phase Type 2 protection for TT and TN systems, with monitoring contacts included. On industrial and infrastructure sites the distribution board is rarely the thing being watched, so a contact that reports an expired module directly into the control system closes a real gap.
Key features
- Type 2 protection for three-phase TT and TN installations, four modules wide
- Monitoring contacts for remote end-of-life signalling to BMS, SCADA or alarm panel
- Pluggable protection modules replaced individually without disturbing terminations
- Local status indication retained for inspection at the board
- Well suited to unmanned sites and to specifications requiring SPD status reporting
Typical applications
Typical homes for this arrester are water and wastewater pumping stations, agricultural and horticultural installations, outdoor process and materials handling plant, telecom and broadcast compounds, and three-phase landlord boards in managed buildings. The signalling contact usually lands on a spare input already present in the panel or outstation.
Compliance
Type 2 devices are classified under the BS EN 61643-11 series and are fitted at distribution boards to limit switching and induced overvoltages. On TT systems the neutral-to-earth path is normally bridged by a spark gap. BS 7671 requires transient overvoltage risk to be assessed and protection provided where the consequences justify it.
Order today for fast UK dispatch, or ask our team for the datasheet figures if you need them for a submission.