DEHN Type 2 Surge Protection Device with Remote Signalling, 2 Module Single Phase TT
- Brand:
- DEHN
- Part number:
- 952115
- EAN:
- 4013364103191
Two-module Type 2 surge arrester for single-phase TT systems with monitoring contacts, so an expired protection module can raise an alarm at a remote panel or BMS.
- Type 2 protection for single-phase TT
- Monitoring contacts for remote alarm
- Two DIN modules, pluggable
- Local status indication
2 in stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Single phase |
|---|---|
| Earthing system | TT, TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TT/TN |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 2 |
|---|
Dimensions
| DIN rail width | 2 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 952115 |
| EAN | 4013364103191 |
| Range | DEHNguard |
More technical data
| Earthing system | single-phase TT (family also covers TN) |
|---|---|
| Status signalling | local indication plus monitoring (remote signalling) contacts |
| Width | 2 DIN modules |
Product details
This is the remote-signalling version of DEHN's two-module Type 2 arrester for single-phase TT installations. TT sites are often the ones nobody visits - a pump house, an outbuilding, a mast - which is exactly where a set of monitoring contacts earns its cost several times over.
Key features
- Type 2 protection for single-phase TT systems, two DIN modules wide
- Monitoring contacts bring end-of-life status back to a BMS, PLC or alarm panel
- Pluggable protection modules replaced individually, leaving the wiring in place
- Local status indication kept for on-site inspection
- Suits electrode-earthed installations where the board is rarely opened
Typical applications
TT earthing is common on farms, rural properties, borehole and sewage pumping stations, telecom and broadcast sites, temporary supplies and marinas - all places where a fault is discovered late. Wiring the monitoring contact into the site controller or telemetry outstation means the protection is reported alongside everything else being monitored.
Compliance
Type 2 devices are classified under the BS EN 61643-11 series and are installed at distribution boards to limit switching and induced overvoltages. On TT systems the neutral-to-earth path is normally bridged by a spark gap. BS 7671 requires transient overvoltage risk to be assessed and protection provided where the consequences justify it.