Trade only · Free delivery over £100 ex VAT
Product image 1

DEHN DEHNguard DG S 275 Type 2 Surge Protection Device, 1 Module Single Phase TN-C-S

Brand:
DEHN
Part number:
952070
EAN:
4013364116269

Single-pole Type 2 surge arrester for single-phase TN-C-S installations, taking one DIN module. Pluggable protection module on a base part, with a green/red status window.

  • Type 2 protection for TN-C-S boards
  • In 20kA, Imax 40kA, UP 1.25kV
  • Single DIN module
  • Pluggable protection module
  • Green/red status indicator
£72.28 ex VAT£86.74 inc VAT

16 in stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

SupplySingle phase
Earthing systemTN-C-S (PME)
Earthing system (as supplied)TN-C-S
Remote signalling contactNo
ApplicationMains AC

Protection

SPD typeType 2
Nominal discharge current (In)20 kA
Max discharge current (Imax)40 kA
Voltage protection level (Up)1.25 kV

Dimensions

DIN rail width1 module

Construction

Replaceable protection moduleYes

Fit

MountingDIN rail

Identification

BrandDEHN
Part number952070
EAN4013364116269
RangeDEHNguard

More technical data

ManufacturerDEHN (DEHNguard S, type DG S 275)
SPD classType 2 to EN 61643-11 / Class II to IEC 61643-1
Max continuous operating voltage (UC)275V a.c. / 350V d.c.
Nominal discharge current In (8/20)20kA; max discharge current Imax: 40kA
Voltage protection level UP1.25kV (1kV at 5kA)
Response time25ns; max mains-side overcurrent protection 125A gL/gG
Short-circuit withstand50kArms; conductor range 1.5 to 35mm2 stranded
EAN as supplied4013364116269
  • Width 1 module (DIN 43880), IP20, 35mm DIN rail to EN 60715, -40 to +80C

Product details

On a TN-C-S supply the protective and neutral conductors are combined up to the intake, so a single-pole arrester between line and PEN does the whole job. The DEHNguard DG S 275 does exactly that in one DIN module, handling a 20kA nominal discharge current while holding the let-through voltage to 1.25kV.

Key features

  • Single-pole Type 2 arrester for single-phase TN-C-S boards, one module wide
  • Pluggable protection module on a base part - swap the module, leave the wiring alone
  • Thermo Dynamic Control monitoring disconnects a failing varistor safely
  • Green/red operating state window shows at a glance whether protection is live
  • Terminals take up to 35mm2 stranded, so it lands comfortably on incoming tails

Typical applications

This is the everyday distribution board arrester for UK domestic and light commercial installations on a PME supply: consumer units and small commercial boards, sub-mains panels feeding IT and comms, EV charge point supplies, solar PV a.c. side connections, and boards serving heat pumps or controls. It limits the switching and induced surges that reach the board from the network and from other loads on the same installation.

Compliance

Tested as a Type 2 device to EN 61643-11 and Class II to IEC 61643-1, with KEMA, VDE, UL, VdS and CSA approvals and a UL 94 V-0 enclosure. IP20, for mounting within an enclosure. BS 7671 requires the risk from transient overvoltages to be assessed and surge protection fitted where the consequences justify it.

Order today for fast UK dispatch on genuine DEHN surge protection at trade-direct prices.