DEHN Type 2 Surge Protection Device with Remote Signalling, 4 Module Three Phase TN
- Brand:
- DEHN
- Part number:
- 952405
- EAN:
- 4013364108462
Four-module Type 2 surge arrester for three-phase TN systems with monitoring contacts, letting an expired protection module raise an alarm at a remote panel or BMS.
- Type 2 protection for three-phase TN
- Monitoring contacts for remote alarm
- Four DIN modules, pluggable
- Local status indication
Out of stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Three phase |
|---|---|
| Earthing system | TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TN |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 2 |
|---|
Dimensions
| DIN rail width | 4 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 952405 |
| EAN | 4013364108462 |
| Range | DEHNguard |
More technical data
| Earthing system | three-phase TN |
|---|---|
| Status signalling | local indication plus monitoring (remote signalling) contacts |
| Width | 4 DIN modules |
Product details
The signalling version of DEHN's four-module three-phase TN arrester. It does the same protective job at the distribution board, and adds a contact set so the control system knows the moment a module reaches the end of its life rather than at the next inspection.
Key features
- Type 2 protection for three-phase TN distribution boards, four modules wide
- Monitoring contacts for remote signalling into BMS, PLC, SCADA or an alarm panel
- Pluggable protection modules keep replacement clear of the field wiring
- Local indication retained for checks made at the board itself
- Meets specifications that require SPD status to be brought back to the control system
Typical applications
Specify it for switchrooms and plant rooms that are visited occasionally, data centre and comms sub-distribution, production and process panels under SCADA supervision, water industry and utility installations, and managed commercial estates where protection status has to be reported centrally rather than checked by eye.
Compliance
Type 2 devices are classified under the BS EN 61643-11 series and are fitted at distribution boards to limit switching and induced overvoltages. BS 7671 requires transient overvoltage risk to be assessed and protection provided where the consequences justify it.
Order today for fast UK dispatch, or contact us for the signalling contact ratings if you need them for a schedule.