DEHN Type 2 Surge Protection Device with Remote Signalling, 2 Module Single Phase TN
- Brand:
- DEHN
- Part number:
- 952205
- EAN:
- 4013364108400
Two-module Type 2 surge arrester for single-phase TN systems fitted with monitoring contacts, allowing end of life to be signalled to a remote alarm, BMS or panel lamp.
- Type 2 protection for single-phase TN
- Monitoring contacts for remote alarm
- Two DIN modules, pluggable
- Local status indication
12 in stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Single phase |
|---|---|
| Earthing system | TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TN |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 2 |
|---|
Dimensions
| DIN rail width | 2 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 952205 |
| EAN | 4013364108400 |
| Range | DEHNguard |
More technical data
| Earthing system | single-phase TN |
|---|---|
| Status signalling | local indication plus monitoring (remote signalling) contacts |
| Width | 2 DIN modules |
Product details
Same duty as the standard two-module TN arrester, with one important addition: a set of monitoring contacts. Where a board is locked, remote or simply never opened, the contact is what turns an expired protection module from an unknown into a logged alarm.
Key features
- Type 2 protection for single-phase TN distribution boards, two modules wide
- Monitoring contacts wire back to a BMS, PLC, telemetry outstation or panel lamp
- Pluggable protection modules for replacement without re-terminating conductors
- Local status indication retained for hands-on inspection
- Supports maintenance regimes that need protection status to be reported, not assumed
Typical applications
Choose the signalling variant for landlord and riser boards, unmanned plant rooms, data and comms rooms, water and wastewater sites, telecom cabinets and multi-site estates run from a central monitoring platform. It is also the sensible option in panels built to a specification that calls for SPD status indication at the control system.
Compliance
Type 2 devices are classified under the BS EN 61643-11 series and are installed at distribution boards to limit switching and induced overvoltages. BS 7671 requires the risk from transient overvoltages to be assessed, with protection provided where the consequences justify it.
Order today for fast UK dispatch, or contact us for the signalling contact ratings if a panel schedule needs them.