Two-module Type 2 surge arrester for TT and TN installations at single phase, using a 1+1 circuit with an N-PE spark gap. Prewired base part with pluggable protection modules.

  • Type 2 protection, single-phase TT and TN
  • 1+1 circuit with N-PE spark gap
  • In 20kA, Imax 40kA, UP 1.25kV
  • Two DIN modules, pluggable
  • Prewired complete unit
£139.95 ex VAT£167.94 inc VAT

Out of stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

SupplySingle phase
Earthing systemTT, TN-S, TN-C-S (PME)
Earthing system (as supplied)TT/TN
Remote signalling contactNo
ApplicationMains AC

Protection

SPD typeType 2
Nominal discharge current (In)20 kA
Max discharge current (Imax)40 kA
Voltage protection level (Up)1.25 kV

Dimensions

DIN rail width2 modules

Construction

Replaceable protection moduleYes

Fit

MountingDIN rail

Identification

BrandDEHN
Part number952110
EAN4013364108417
RangeDEHNguard

More technical data

ManufacturerDEHN (DEHNguard modular, type DG M TT 2P 275)
SPD classType 2 to EN 61643-11 / Class II to IEC 61643-1
Nominal a.c. voltage (UN)230V; UC 275V (L-N), 255V (N-PE)
Nominal discharge current In (8/20)20kA; max discharge current Imax: 40kA
Lightning impulse current N-PE (10/350) Iimp12kA
Voltage protection level UP1.25kV (L-N), 1.5kV (N-PE); 1kV at 5kA
Follow current extinguishing capability N-PE100Arms; response time 25ns (L-N)
  • Width 2 modules (DIN 43880), IP20, 35mm DIN rail to EN 60715, -40 to +80C

Product details

TT installations need a different arrester topology to TN, because the neutral-to-earth path has to be bridged by a spark gap rather than a varistor. The DEHNguard DG M TT 2P 275 uses that 1+1 arrangement in two DIN modules, giving single-phase TT and TN boards full Type 2 protection with a 12kA lightning impulse rating on the N-PE path.

Key features

  • 1+1 circuit with an N-PE spark gap, suitable for single-phase TT as well as TN systems
  • Prewired complete unit - the base part arrives ready to land on incoming conductors
  • Pluggable protection modules, replaced individually without disturbing terminations
  • Thermo Dynamic Control monitoring for safe disconnection of a failing varistor
  • Follow current extinguishing capability of 100Arms on the N-PE path

Typical applications

Fit it at the origin or the main distribution board of single-phase installations with a TT earth - rural and agricultural properties, sites on their own earth electrode, park homes and caravan sites, temporary building supplies, and marina and outbuilding boards. The same unit works on TN systems, so it suits contractors who want one arrester that covers both earthing arrangements.

Compliance

Tested as a Type 2 device to EN 61643-11 and Class II to IEC 61643-1, with KEMA, VDE, UL and VdS approvals and a UL 94 V-0 enclosure rated IP20. BS 7671 requires the risk from transient overvoltages to be assessed and coordinated surge protection provided where the consequences justify it.