
DEHN DEHNguard DG M TN 275 Type 2 Surge Protection Device, 2 Module Single Phase TN
- Brand:
- DEHN
- Part number:
- 952200
- EAN:
- 4013364108394
Two-module Type 2 surge arrester for single-phase TN systems, supplied prewired with pluggable protection modules and a green/red status window.
- Type 2 protection for single-phase TN
- In 20kA, Imax 40kA, UP 1.25kV
- Two DIN modules, prewired
- Pluggable protection modules
- Green/red status indicator
Out of stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Single phase |
|---|---|
| Earthing system | TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TN |
| Remote signalling contact | No |
| Application | Mains AC |
Protection
| SPD type | Type 2 |
|---|---|
| Nominal discharge current (In) | 20 kA |
| Max discharge current (Imax) | 40 kA |
| Voltage protection level (Up) | 1.25 kV |
Dimensions
| DIN rail width | 2 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 952200 |
| EAN | 4013364108394 |
| Range | DEHNguard |
More technical data
| Manufacturer | DEHN (DEHNguard modular, type DG M TN 275) |
|---|---|
| SPD class | Type 2 to EN 61643-11 / Class II to IEC 61643-1 |
| Nominal a.c. voltage (UN) | 230V; max continuous operating voltage (UC): 275V |
| Nominal discharge current In (8/20) | 20kA; max discharge current Imax: 40kA |
| Voltage protection level UP | 1.25kV (1kV at 5kA); response time 25ns |
| Max mains-side overcurrent protection | 125A gL/gG; short-circuit withstand 50kArms |
| Conductor range | 1.5 to 35mm2 stranded / 25mm2 flexible |
- Width 2 modules (DIN 43880), IP20, 35mm DIN rail to EN 60715, -40 to +80C
Product details
The DEHNguard DG M TN 275 is the workhorse Type 2 arrester for single-phase TN boards. Two DIN modules, prewired, with a 20kA nominal discharge current and a let-through voltage held to 1.25kV - enough headroom for the switching and induced surges that reach a distribution board day to day.
Key features
- Type 2 protection for single-phase TN systems in a prewired two-module unit
- Pluggable protection modules on a base part, so replacement leaves wiring undisturbed
- Thermo Dynamic Control monitoring disconnects a failing varistor before it overheats
- Green/red operating state window gives an unambiguous visual check
- Withstands a 50kArms prospective short circuit behind a 125A gL/gG backup fuse
Typical applications
This is the device to fit at main and sub-distribution boards on TN-S and TN-C-S supplies: commercial and industrial panel boards, landlord and riser boards, machinery supply panels, IT and comms sub-mains, and boards feeding controls, drives and metering. It is also the natural second stage downstream of a Type 1 arrester at the origin of a building with a lightning protection system.
Compliance
Tested as a Type 2 device to EN 61643-11 and Class II to IEC 61643-1, with KEMA, VDE, UL and VdS approvals and a UL 94 V-0 enclosure rated IP20. BS 7671 requires the risk from transient overvoltages to be assessed, with coordinated surge protection provided where the consequences justify it.
Order today for fast UK dispatch on genuine DEHN surge protection at trade-direct prices.



