Mersen Surge-Trap STPT2-40K275V-4PM Type 2 Surge Protection Device, 4 Pole TN-S
- Brand:
- Mersen
- Part number:
- 83020153
- EAN:
- 8435297849247
Four-pole pluggable Type 2 surge arrester for three-phase TN-S systems at 230/400V, rated Imax 40kA per pole with a remote end-of-life contact.
- Type 2 protection for three-phase TN-S
- Imax 40kA, In 20kA, Up 1.3kV
- Remote end-of-life contact
- Plug-in coded cartridges
- One cartridge type for all poles
Out of stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Three phase |
|---|---|
| Earthing system | TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TN |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 2 |
|---|---|
| Nominal discharge current (In) | 20 kA |
| Max discharge current (Imax) | 40 kA |
| Voltage protection level (Up) | 1.3 kV |
Dimensions
| DIN rail width | 4 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | Mersen |
|---|---|
| Part number | 83020153 |
| EAN | 8435297849247 |
| Range | Mersen Surge-Trap STPT2 |
More technical data
| Manufacturer | Mersen (Surge-Trap STPT2, catalogue STPT2-40K275V-4PM) |
|---|---|
| SPD class | Type 2 / Class II to IEC 61643-11 and EN 61643-11 |
| System | TN-S, three phase plus neutral; Un 230/400 VAC; Uc 275V |
| Max discharge current Imax (8/20) | 40kA; nominal discharge current In: 20kA |
| Voltage protection level Up at In | 1.3kV |
| Remote contact | yes; cartridge SP2-40K275V |
- Response time 25ns; back-up fuse 125A gG; Icc 25kA
- IP20, PA66 CT1 V-0 body, -40 to +80C, reversible chassis
Product details
This is the four-pole TN-S version of Mersen's Surge-Trap STPT2 distribution board arrester. All four poles take the same 275V cartridge, each rated at 40kA maximum discharge current, holding the protection level to 1.3kV across a 230/400V three-phase supply.
Key features
- Type 2 / Class II protection for three-phase TN-S distribution boards
- Four poles sharing one cartridge type, simplifying spares holding
- Imax of 40kA, In of 20kA and a 1.3kV protection level per pole
- Mechanically coded plug-in cartridges for straightforward replacement
- Visual and remote end-of-life indicators, 25ns response time
Typical applications
Specify it for three-phase supply distribution panels in factories and workshops, warehouses and cold stores, data centres and comms rooms, commercial building plant rooms, and process and automation panels - either downstream of a Type 1 device or as first-stage protection where no direct strike risk exists.
Compliance
Tested to IEC 61643-11 and EN 61643-11 as a Type 2 / Class II device, with a PA66 CT1 V-0 body and IP20 protection. BS 7671 requires the risk from transient overvoltages to be assessed, with coordinated protection provided where the consequences justify it.
Order today for fast UK dispatch on genuine Mersen surge protection at trade-direct prices.