Trade only · Free delivery over £100 ex VAT
Product image coming soon

Terasaki 001253 Under-Voltage Release 200-240V DC, for TemBreak 2 MCCBs up to 400A

Brand:
Terasaki
Part number:
001253

Under-voltage release with a 200-240 V DC coil for TemBreak 2 MCCBs on the 160 A, 250 A and 400 A frames, for 220 V DC control systems. Terasaki part number 001253.

  • 200-240 V DC coil for 220 V DC batteries
  • Opens the breaker if the DC supply is lost
  • Fail-safe stop chains via a normally closed contact
  • TemBreak 2 160 A, 250 A and 400 A frames
£105.53 ex VAT£126.64 inc VAT

Available to order

Datasheet (PDF)Opens in a new tabBuild a board with this partConfigure a complete Terasaki Resilience panel board online: incomer, outgoing MCCBs, surge and metering, with a drawing and parts list.

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 3-5 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

Coil voltage200-240 V DC

Fit

Fits deviceTerasaki S160-NF, Terasaki S160-NJ, Terasaki S160-GJ, Terasaki S250-NJ, Terasaki S250-GJ, Terasaki S250-NE, Terasaki S250-GE, Terasaki S400-NN, Terasaki S400-NJ, Terasaki S400-NE
Fits MCCB frame160 A, 250 A, 400 A
Panelboard rangeResilience Standard, Resilience Plus
What does this mean?

Incomer and outgoing ways in one wall-mounted board. 250 A or 400 A busbars, 4 to 18 outgoing ways, outgoing MCCBs up to 125 A, Form 3b Type 2, doors included. Modular: a separate incomer housing beside the panel board, with add-on enclosures and cableways. 400 A or 800 A busbars, 6 to 18 outgoing ways, outgoing MCCBs up to 250 A (400 A on the twin board), Form 3a or 3b Type 2, doors optional.

Identification

BrandTerasaki
Part number001253
RangeTerasaki TemBreak2
TypeUnder-voltage release

More technical data

Typeunder-voltage release, internal
Coil200-240 V DC
Actiontrips on loss of coil voltage
Breaker frames160 A, 250 A and 400 A TemBreak 2
Not witha shunt trip
Suppliedone release with fitting instructions

Product details

Terasaki 001253 is an under-voltage release with a 200-240 V DC coil, for TemBreak 2 MCCBs where the control system runs from a 220 V DC battery. Installed in a breaker on the 160 A, 250 A or 400 A frame, it opens the breaker if the DC voltage disappears and holds it off until the supply is back.

Key features

  • 200-240 V DC coil for 220 V DC battery systems
  • Opens the breaker on loss of DC voltage; reclosing waits for its return
  • Remote tripping through a normally closed contact in series with the coil supply
  • Fits in the trip-coil position under the front cover, without special tools
  • One per breaker, in place of a shunt trip

Typical applications

Power stations, large switchrooms and process plants with 220 V DC auxiliary systems, where circuits must be disconnected if the DC supply is lost, and fail-safe emergency stop chains run at that voltage. Time-delayed tripping on TemBreak 2 uses an external controller that clips to the side of the breaker.

For TemBreak 2 S160-NF, S160-NJ, S160-GJ, S250-NJ, S250-GJ, S250-NE, S250-GE, S400-NJ and S400-NE MCCBs and the S400-NN switch-disconnector. For a 230 V AC supply, the AC version is 001215.

Genuine Terasaki product. Add it to your cart.