Trade only · Free delivery over £100 ex VAT
Product image coming soon

Terasaki 001239 Under-Voltage Release 24V DC, for TemBreak 2 MCCBs up to 400A

Brand:
Terasaki
Part number:
001239

Under-voltage release with a 24 V DC coil for fail-safe tripping of TemBreak 2 MCCBs on the 160 A, 250 A and 400 A frames. Terasaki part number 001239.

  • 24 V DC coil for safety relays and PLCs
  • Fail-safe: trips when 24 V is removed
  • Blocks reclosing until the coil is re-energised
  • TemBreak 2 160 A, 250 A and 400 A frames
£105.53 ex VAT£126.64 inc VAT

Available to order

Datasheet (PDF)Opens in a new tabBuild a board with this partConfigure a complete Terasaki Resilience panel board online: incomer, outgoing MCCBs, surge and metering, with a drawing and parts list.

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 3-5 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

Coil voltage24 V DC

Fit

Fits deviceTerasaki S160-NF, Terasaki S160-NJ, Terasaki S160-GJ, Terasaki S250-NJ, Terasaki S250-GJ, Terasaki S250-NE, Terasaki S250-GE, Terasaki S400-NN, Terasaki S400-NJ, Terasaki S400-NE
Fits MCCB frame160 A, 250 A, 400 A
Panelboard rangeResilience Standard, Resilience Plus
What does this mean?

Incomer and outgoing ways in one wall-mounted board. 250 A or 400 A busbars, 4 to 18 outgoing ways, outgoing MCCBs up to 125 A, Form 3b Type 2, doors included. Modular: a separate incomer housing beside the panel board, with add-on enclosures and cableways. 400 A or 800 A busbars, 6 to 18 outgoing ways, outgoing MCCBs up to 250 A (400 A on the twin board), Form 3a or 3b Type 2, doors optional.

Identification

BrandTerasaki
Part number001239
RangeTerasaki TemBreak2
TypeUnder-voltage release

More technical data

Typeunder-voltage release, internal
Coil24 V DC
Actiontrips on loss of coil voltage
Breaker frames160 A, 250 A and 400 A TemBreak 2
Not witha shunt trip
Suppliedone release with fitting instructions

Product details

Terasaki 001239 is a 24 V DC under-voltage release for TemBreak 2 MCCBs on the 160 A, 250 A and 400 A frames. The breaker can stay closed only while the 24 V DC coil is energised, so a safety relay, PLC output or emergency stop chain at 24 V DC trips the breaker simply by removing that voltage.

Key features

  • 24 V DC coil to match safety relay and PLC control voltages
  • Trips when the 24 V supply is removed, interrupted or lost
  • Breaker cannot be reclosed until the coil is energised again
  • Clicks into the trip-coil position under the front cover; field-fittable
  • One coil position per breaker: under-voltage release or shunt trip

Typical applications

Fail-safe emergency stop and safety relay circuits at 24 V DC, PLC-controlled isolation where losing the control signal must open the breaker, and fire alarm interfaces that remove a 24 V supply to shut plant down. If the 24 V supply itself fails, the breaker trips too, so feed the release from a reliable or battery-backed source. Delayed tripping needs the external clip-on time-delay controller.

Fits the TemBreak 2 S160-NF, S160-NJ and S160-GJ, the S250-NJ, S250-GJ, S250-NE and S250-GE, the S400-NJ and S400-NE MCCBs, and the S400-NN switch-disconnector, including those in Resilience Standard and Resilience Plus panel boards.

Genuine Terasaki product. Add it to your cart.