Under-voltage release with a 100-120 V AC coil that trips TemBreak 2 MCCBs on the 160 A, 250 A and 400 A frames when the coil supply is lost. Terasaki part number 001208.
- 100-120 V AC coil for 110 V control circuits
- Trips on loss of supply, fail-safe
- Blocks reclosing until the voltage returns
- TemBreak 2 160 A, 250 A and 400 A frames
Available to order
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 3-5 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Coil voltage | 100-120 V AC |
|---|
Fit
| Fits device | Terasaki S160-NF, Terasaki S160-NJ, Terasaki S160-GJ, Terasaki S250-NJ, Terasaki S250-GJ, Terasaki S250-NE, Terasaki S250-GE, Terasaki S400-NN, Terasaki S400-NJ, Terasaki S400-NE |
|---|---|
| Fits MCCB frame | 160 A, 250 A, 400 A |
| Panelboard range | Resilience Standard, Resilience PlusWhat does this mean?Incomer and outgoing ways in one wall-mounted board. 250 A or 400 A busbars, 4 to 18 outgoing ways, outgoing MCCBs up to 125 A, Form 3b Type 2, doors included. Modular: a separate incomer housing beside the panel board, with add-on enclosures and cableways. 400 A or 800 A busbars, 6 to 18 outgoing ways, outgoing MCCBs up to 250 A (400 A on the twin board), Form 3a or 3b Type 2, doors optional. |
Identification
| Brand | Terasaki |
|---|---|
| Part number | 001208 |
| Range | Terasaki TemBreak2 |
| Type | Under-voltage release |
More technical data
| Type | under-voltage release, internal |
|---|---|
| Coil | 100-120 V AC |
| Action | trips when the coil voltage is lost; the breaker stays off until it returns |
| Breaker frames | 160 A, 250 A and 400 A TemBreak 2 (the 800 A to 1600 A frames use a larger release) |
| Not with | a shunt trip in the same breaker |
| Supplied | one release with fitting instructions |
Product details
The Terasaki 001208 under-voltage release trips a TemBreak 2 MCCB when the 100-120 V AC supply to its coil drops away, and the breaker cannot be closed again until that voltage returns. It is the version for 110 V AC control circuits, typically fed from a control transformer, on breakers of the 160 A, 250 A and 400 A frames.
Key features
- 100-120 V AC coil for 110 V and 120 V AC control circuits
- Fail-safe: a lost supply, broken wire or opened stop contact all trip the breaker
- Remote tripping by a normally closed pushbutton or contact wired in series with the coil supply
- Internal accessory in the trip-coil position, fitted after unclipping the front cover
- Shares that position with the shunt trip: one or the other per breaker
Typical applications
Stopping motors and machinery restarting on their own when power returns after an outage, fail-safe emergency stop chains in 110 V AC control panels, and interlocks that must drop a load when a control supply is lost. If the trip must be delayed, TemBreak 2 does this with an external time-delay controller that clips to the side of the breaker.
Fits TemBreak 2 S160-NF, S160-NJ, S160-GJ, S250-NJ, S250-GJ, S250-NE, S250-GE, S400-NJ and S400-NE MCCBs and the S400-NN switch-disconnector, including those in Resilience Standard and Resilience Plus panel boards.
Add it to your cart, or ask us which coil voltage suits your control circuit.