Europa ATS-CON404PME 40A 4-Pole Three Phase Automatic Transfer Switch, 415V
- Brand:
- Europa Components
- Part number:
- ATS-CON404PME
- EAN:
- 5056551200562
A 40 A four-pole three-phase automatic transfer switch for 415 V supplies. It detects a mains failure, starts the generator and transfers the load without an operator.
- 40 A AC1 three-phase automatic transfer
- Four-pole 415 V, phases and neutral
- Mains failure detection with generator start
- Adjustable start, changeover, return and cool-down timers
- Built to BS EN IEC 60947-6-1
7 in stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Rated current | 40 A |
|---|---|
| Poles / neutral | 4 pole |
| Neutral | Switched neutral |
| Supply | Three phase |
| Utilisation category | AC-1 |
| Voltage | 400/415 V |
Protection
| Door interlock | No |
|---|
Construction
| Enclosure material | Sheet steel |
|---|
Identification
| Brand | Europa Components |
|---|---|
| Part number | ATS-CON404PME |
| EAN | 5056551200562 |
| Range | Europa ATS |
| Type | Automatic transfer switch |
More technical data
| Rated operational current | 40 A, AC1 |
|---|---|
| Poles | 4, three phase 415 V |
| Maximum cable size | 10 sq mm |
| Switching | contactor-based, mains and generator sources |
| Control | mains failure relay plus delay-on-start, changeover, mains return and cool-down timers |
Product details
The Europa ATS-CON404PME is a 40 A four-pole automatic transfer switch for 415 V three-phase installations. It replaces the walk-to-the-switch routine of a manual changeover with a controlled sequence: monitor the mains, call the generator, wait out the run-up, transfer the load, and hand it back once the incoming supply has proved itself again.
Key features
- 40 A operational current in category AC1 across four poles at 415 V
- Three phases and neutral transferred together on contactor switching
- Mains failure relay with adjustable over-voltage, under-voltage, hysteresis and delay
- Delay-on-start timer avoids calling the generator on a momentary dip
- Changeover, mains return and cool-down timers complete the sequence unattended
Typical applications
A 40 A three-phase ATS suits small plant that must keep running: booster and sump pump sets, refrigeration packs, small process skids, comms and telemetry cabinets, and lift or fire-system supplies on modest buildings. It is also a straightforward retrofit where a site already has a generator but is transferring by hand.
Compliance
Europa lists this automatic transfer switch to BS, EN and IEC 60947-6-1, the standard covering low-voltage multiple-function switching equipment such as transfer switching equipment. The control devices are DIN rail mounted to EN and IEC 60715.
Order the ATS-CON404PME for fast UK dispatch, or ask our technical team how the timers should be set for your generator.