Europa ATS-CON402PME 40A 2-Pole Single Phase Automatic Transfer Switch, 230V
- Brand:
- Europa Components
- Part number:
- ATS-CON402PME
- EAN:
- 5056551200555
A 40 A two-pole single-phase automatic transfer switch for 230 V supplies. It detects mains failure, signals the generator to start and transfers the load without anyone attending site.
- 40 A AC1 single-phase automatic transfer
- Two-pole 230 V, line and neutral
- Mains failure detection with generator start
- Adjustable start, changeover, return and cool-down timers
- Built to BS EN IEC 60947-6-1
2 in stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Rated current | 40 A |
|---|---|
| Poles / neutral | 2 pole |
| Neutral | No neutral |
| Supply | Single phase |
| Utilisation category | AC-1 |
| Voltage | 230 V |
Protection
| Door interlock | No |
|---|
Construction
| Enclosure material | Sheet steel |
|---|
Identification
| Brand | Europa Components |
|---|---|
| Part number | ATS-CON402PME |
| EAN | 5056551200555 |
| Range | Europa ATS |
| Type | Automatic transfer switch |
More technical data
| Rated operational current | 40 A, AC1 |
|---|---|
| Poles | 2, single phase 230 V |
| Maximum cable size | 10 sq mm |
| Switching | contactor-based, mains and generator sources |
| Control | mains failure relay plus delay-on-start, changeover, mains return and cool-down timers |
Product details
The Europa ATS-CON402PME is a 40 A single-phase automatic transfer switch that watches the incoming 230 V mains and moves the load to a standby generator on its own. Where a manual changeover needs somebody to walk to the switch, this unit detects the failure, calls the generator, waits for it to come up to speed and transfers, then puts the load back on the mains when the supply returns.
Key features
- 40 A operational current in category AC1, switching line and neutral on two poles
- Mains failure relay with adjustable over-voltage and under-voltage thresholds, hysteresis and time delay
- Delay-on-start timer sets how long to wait before calling the generator
- Changeover timer holds the transfer until the set has reached speed and voltage
- Mains return and cool-down timers restore the load and stop the set cleanly
Typical applications
A 40 A single-phase ATS suits small premises that cannot be left dark: village surgeries and pharmacies, small care homes, telemetry and telecoms cabinets, CCTV and security compounds, sump and sewage pumps, and cold storage for stock or medication. It is also used on rural properties with a permanently installed standby set.
Compliance
Europa lists this automatic transfer switch to BS, EN and IEC 60947-6-1, the standard covering low-voltage multiple-function switching equipment such as transfer switching equipment. The control devices are DIN rail mounted to EN and IEC 60715.
Order the ATS-CON402PME for fast UK dispatch, or talk to our technical team about generator start contacts and timer settings before commissioning.