DEHN DV M TT 2P 255 FM Type 1+2 Surge Protection Device with Remote Signalling, 4 Module TT/TN
- Brand:
- DEHN
- Part number:
- 951115
- EAN:
- 4013364120716
Four-module Type 1+2 arrester for TT and TN installations at single phase, with a remote signalling changeover contact for end-of-life alarm.
- Combined Type 1+2 protection
- Changeover contact for remote alarm
- Itotal 50kA, UP 1.5kV
- Single-phase TT and TN, 1+1 circuit
- Four DIN modules
Out of stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Single phase |
|---|---|
| Earthing system | TT, TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TT/TN |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 1+2 |
|---|---|
| Total discharge current (Itotal) | 50 kA |
| Voltage protection level (Up) | 1.5 kV |
Dimensions
| DIN rail width | 4 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 951115 |
| EAN | 4013364120716 |
| Range | DEHNventil |
More technical data
| Manufacturer | DEHN (DEHNventil modular, type DV M TT 2P 255 FM) |
|---|---|
| SPD class | Type 1 / Class I to EN 61643-11 / IEC 61643-1 |
| Nominal a.c. voltage (UN) | 230V; max continuous operating voltage (UC): 255V |
| Lightning impulse current L+N-PE Itotal (10/350) | 50kA; Iimp 25kA (L-N) / 50kA (N-PE) |
| Nominal discharge current In (8/20) | 25 / 50kA; voltage protection level UP: 1.5kV |
| Follow current extinguishing capability | 50kArms (L-N), 100Arms (N-PE) |
| Remote signalling | changeover contact, 250V/0.5A a.c., 250V/0.1A d.c. |
- Max backup fuse 315A gL/gG to 50kArms; width 4 modules, IP20, -40 to +80C
Product details
This is the remote-signalling version of DEHN's single-phase combined arrester. Alongside the same spark-gap performance - 50kA total lightning impulse current and a 1.5kV protection level - it carries a changeover contact rated 250V/0.5A a.c., so the installation reports the state of its own front-line protection.
Key features
- Combined Type 1 and Type 2 protection with remote signalling built in
- Changeover contact rated 250V / 0.5A a.c. for alarm, BMS or telemetry connection
- 1+1 circuit for single-phase TT and TN systems, prewired across four modules
- RADAX Flow follow current limitation avoids nuisance operation of upstream fuses
- Pluggable protection modules, replaceable without disturbing the main terminations
Typical applications
Origin-position protection on sites nobody visits regularly is exactly where remote signalling pays: unmanned pumping and treatment stations, telecoms and broadcast compounds, mast and monitoring installations, farm buildings and remote industrial units fed by overhead lines. The changeover contact suits both a simple panel lamp and an input on a telemetry outstation.
Compliance
Tested as a Type 1 / Class I device to EN 61643-11 and IEC 61643-1, with KEMA, VDE, UL and VdS approvals, a UL 94 V-0 enclosure and IP20 protection. Energy coordination is declared with Type 2 equipment and with Type 3 equipment within 5m. BS 7671 requires transient overvoltage risk to be assessed and appropriate protection provided.