DEHN DV M TT 2P 255 FM Type 1+2 Surge Protection Device with Remote Signalling, 4 Module TT/TN

Brand:
DEHN
Part number:
951115
EAN:
4013364120716

Four-module Type 1+2 arrester for TT and TN installations at single phase, with a remote signalling changeover contact for end-of-life alarm.

  • Combined Type 1+2 protection
  • Changeover contact for remote alarm
  • Itotal 50kA, UP 1.5kV
  • Single-phase TT and TN, 1+1 circuit
  • Four DIN modules
£1,250.02 ex VAT£1,500.02 inc VAT

Out of stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

SupplySingle phase
Earthing systemTT, TN-S, TN-C-S (PME)
Earthing system (as supplied)TT/TN
Remote signalling contactYes
ApplicationMains AC

Protection

SPD typeType 1+2
Total discharge current (Itotal)50 kA
Voltage protection level (Up)1.5 kV

Dimensions

DIN rail width4 modules

Construction

Replaceable protection moduleYes

Fit

MountingDIN rail

Identification

BrandDEHN
Part number951115
EAN4013364120716
RangeDEHNventil

More technical data

ManufacturerDEHN (DEHNventil modular, type DV M TT 2P 255 FM)
SPD classType 1 / Class I to EN 61643-11 / IEC 61643-1
Nominal a.c. voltage (UN)230V; max continuous operating voltage (UC): 255V
Lightning impulse current L+N-PE Itotal (10/350)50kA; Iimp 25kA (L-N) / 50kA (N-PE)
Nominal discharge current In (8/20)25 / 50kA; voltage protection level UP: 1.5kV
Follow current extinguishing capability50kArms (L-N), 100Arms (N-PE)
Remote signallingchangeover contact, 250V/0.5A a.c., 250V/0.1A d.c.
  • Max backup fuse 315A gL/gG to 50kArms; width 4 modules, IP20, -40 to +80C

Product details

This is the remote-signalling version of DEHN's single-phase combined arrester. Alongside the same spark-gap performance - 50kA total lightning impulse current and a 1.5kV protection level - it carries a changeover contact rated 250V/0.5A a.c., so the installation reports the state of its own front-line protection.

Key features

  • Combined Type 1 and Type 2 protection with remote signalling built in
  • Changeover contact rated 250V / 0.5A a.c. for alarm, BMS or telemetry connection
  • 1+1 circuit for single-phase TT and TN systems, prewired across four modules
  • RADAX Flow follow current limitation avoids nuisance operation of upstream fuses
  • Pluggable protection modules, replaceable without disturbing the main terminations

Typical applications

Origin-position protection on sites nobody visits regularly is exactly where remote signalling pays: unmanned pumping and treatment stations, telecoms and broadcast compounds, mast and monitoring installations, farm buildings and remote industrial units fed by overhead lines. The changeover contact suits both a simple panel lamp and an input on a telemetry outstation.

Compliance

Tested as a Type 1 / Class I device to EN 61643-11 and IEC 61643-1, with KEMA, VDE, UL and VdS approvals, a UL 94 V-0 enclosure and IP20 protection. Energy coordination is declared with Type 2 equipment and with Type 3 equipment within 5m. BS 7671 requires transient overvoltage risk to be assessed and appropriate protection provided.