DEHN DEHNventil DV M TT 2P 255 Type 1+2 Surge Protection Device, 4 Module Single Phase TT/TN

Brand:
DEHN
Part number:
951110
EAN:
4013364113312

Four-module spark-gap Type 1+2 arrester for TT and TN installations at single phase, using a 1+1 circuit with RADAX Flow follow current limitation.

  • Combined Type 1+2 protection
  • Single-phase TT and TN, 1+1 circuit
  • Itotal 50kA, UP 1.5kV
  • RADAX Flow follow current limitation
  • Four DIN modules, pluggable
£898.61 ex VAT£1,078.33 inc VAT

Out of stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

SupplySingle phase
Earthing systemTT, TN-S, TN-C-S (PME)
Earthing system (as supplied)TT/TN
Remote signalling contactNo
ApplicationMains AC

Protection

SPD typeType 1+2
Total discharge current (Itotal)50 kA
Voltage protection level (Up)1.5 kV

Dimensions

DIN rail width4 modules

Construction

Replaceable protection moduleYes

Fit

MountingDIN rail

Identification

BrandDEHN
Part number951110
EAN4013364113312
RangeDEHNventil

More technical data

ManufacturerDEHN (DEHNventil modular, type DV M TT 2P 255)
SPD classType 1 / Class I to EN 61643-11 / IEC 61643-1
Nominal a.c. voltage (UN)230V; max continuous operating voltage (UC): 255V
Lightning impulse current L+N-PE Itotal (10/350)50kA; Iimp 25kA (L-N) / 50kA (N-PE)
Nominal discharge current In (8/20)25 / 50kA; voltage protection level UP: 1.5kV
Follow current extinguishing capability50kArms (L-N), 100Arms (N-PE)
Max backup fuse315A gL/gG up to 50kArms; response time 100ns
EAN as supplied4013364113312
  • Conductor range 10 to 50mm2 stranded; width 4 modules, IP20, -40 to +80C

Product details

Where a single-phase installation needs Type 1 and Type 2 duty in one device, the DEHNventil DV M TT 2P 255 covers both. Its spark-gap technology carries a 50kA total lightning impulse current on the L+N-PE path, holds the protection level to 1.5kV, and is capable of protecting terminal equipment directly.

Key features

  • Combined Type 1 and Type 2 arrester in a prewired four-module unit
  • 1+1 circuit for single-phase TT and TN systems, with an N-PE spark gap
  • RADAX Flow follow current limitation keeps a 20A gL/gG fuse from tripping to 50kArms
  • Pluggable protection modules replaced individually without disturbing the wiring
  • Capable of protecting terminal equipment, with Type 3 coordination within 5m

Typical applications

Fit it at the origin of single-phase installations exposed to direct lightning current - buildings with an external lightning protection system, overhead-fed rural properties, telemetry and pumping stations, masts and farm buildings on a TT earth. Because it is coordinated for terminal equipment, one device can often replace a separate Type 1 and Type 2 arrangement.

Compliance

Tested as a Type 1 / Class I device to EN 61643-11 and IEC 61643-1, with KEMA, VDE, UL and VdS approvals, a UL 94 V-0 enclosure and IP20 protection. Energy coordination is declared with Type 2 equipment, and with Type 3 equipment within 5m. BS 7671 requires transient overvoltage risk to be assessed, with Type 1 protection where partial lightning current may enter the installation.

Order today for fast UK dispatch on genuine DEHN combined arresters at trade-direct prices.