Trade only · Free delivery over £100 ex VAT
Product image 1

DEHN Combined Type 1+2 Surge Protection Device, 8 Module Three Phase TPN TN

Brand:
DEHN
Part number:
951400
EAN:
4013364149816

Eight-module combined lightning current and surge arrester configured for three-phase and neutral TN installations, fitted at the origin of the installation.

  • Combined Type 1+2 protection
  • Three-phase and neutral TN
  • Eight DIN modules
  • Origin-of-installation device
£892.04 ex VAT£1,070.45 inc VAT

Out of stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

SupplyThree phase
Earthing systemTN-S, TN-C-S (PME)
Earthing system (as supplied)TN
Remote signalling contactNo
ApplicationMains AC

Protection

SPD typeType 1+2

Dimensions

DIN rail width8 modules

Construction

Replaceable protection moduleYes

Fit

MountingDIN rail

Identification

BrandDEHN
Part number951400
EAN4013364149816
RangeDEHNventil

More technical data

SPD classcombined Type 1 and Type 2
Configurationthree phase and neutral (TPN), TN earthing system
Width8 DIN modules
Formatmodular arrester with pluggable protection modules

Product details

Configured for TPN supplies on a TN earthing system, this eight-module DEHN combined Type 1 and 2 arrester takes the partial lightning current a direct strike can inject into the installation, and limits the switching and induced surges that arrive under normal operation.

Key features

  • Combined Type 1 and Type 2 protection for three-phase and neutral TN installations
  • Eight DIN modules, providing protection on all four conductors
  • Fitted at the origin of the installation ahead of the distribution boards
  • Modular construction allows individual protection modules to be changed in service
  • One device covering both lightning current and surge duties at the intake

Typical applications

Typical installations are TPN intake panels in factories, warehouses and distribution centres, commercial buildings with an external lightning protection system, plant rooms and switchrooms fed from a nearby substation, and industrial sites on exposed ground. Type 2 devices at the distribution boards then complete the coordinated scheme.

Compliance

Combined Type 1 and Type 2 devices are classified under the BS EN 61643-11 series and are installed at the origin of the installation. BS 7671 requires transient overvoltage risk to be assessed, with Type 1 protection where partial lightning current may enter the installation.

Order today for fast UK dispatch, or contact us for the full ratings if you need them for a design submission.