
DEHN Combined Type 1+2 Surge Protection Device with Remote Signalling, 4 Module Single Phase TN
- Brand:
- DEHN
- Part number:
- 951205
- EAN:
- 4013364376632
Four-module Type 1+2 arrester for TN installations at single phase, with monitoring contacts so end of life can be alarmed at a remote panel or BMS.
- Combined Type 1+2 protection
- Single-phase TN configuration
- Monitoring contacts for remote alarm
- Four DIN modules
18 in stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Supply | Single phase |
|---|---|
| Earthing system | TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | TN |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 1+2 |
|---|
Dimensions
| DIN rail width | 4 modules |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 951205 |
| EAN | 4013364376632 |
| Range | DEHNventil |
More technical data
| SPD class | combined Type 1 and Type 2 |
|---|---|
| Configuration | single phase, TN earthing system |
| Status signalling | local indication plus monitoring (remote signalling) contacts |
| Width | 4 DIN modules |
Product details
Origin-of-installation protection is the part of a surge scheme least likely to be inspected, because the intake cupboard is rarely opened. This four-module combined Type 1 and 2 arrester for single-phase TN systems includes monitoring contacts, so the state of that first line of defence is reported rather than assumed.
Key features
- Combined Type 1 and Type 2 protection for single-phase TN installations
- Monitoring contacts for remote end-of-life signalling to BMS, alarm panel or telemetry
- Four DIN modules, mounting on standard 35mm rail at the intake position
- Pluggable protection modules for replacement without re-terminating conductors
- Local status indication retained for checks made at the board
Typical applications
Use it at intake positions on sites that are monitored remotely rather than staffed: telemetry and pumping stations, telecoms cabinets, unmanned industrial units, agricultural buildings with lightning protection, and single-phase supplies on exposed rural sites. The contact brings the SPD into the same reporting regime as the rest of the site plant.
Compliance
Combined Type 1 and Type 2 devices are classified under the BS EN 61643-11 series and are installed at the origin of the installation, coordinated with Type 2 protection downstream. BS 7671 requires transient overvoltage risk to be assessed and appropriate protection provided.
Order today for fast UK dispatch, or contact us for the signalling contact ratings if a panel schedule needs them.





