DEHN Combined Type 1+2 Surge Protection Device, 4 Module Single Phase TN

Brand:
DEHN
Part number:
951200
EAN:
4013364124035

Four-module Type 1+2 arrester for TN installations at single phase, fitted at the origin to handle partial lightning currents and switching surges.

  • Combined Type 1+2 protection
  • Single-phase TN configuration
  • Four DIN modules
  • Origin-of-installation device
£602.40 ex VAT£722.88 inc VAT

3 in stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

SupplySingle phase
Earthing systemTN-S, TN-C-S (PME)
Earthing system (as supplied)TN
Remote signalling contactNo
ApplicationMains AC

Protection

SPD typeType 1+2

Dimensions

DIN rail width4 modules

Construction

Replaceable protection moduleYes

Fit

MountingDIN rail

Identification

BrandDEHN
Part number951200
EAN4013364124035
RangeDEHNventil

More technical data

SPD classcombined Type 1 and Type 2
Configurationsingle phase (SPN), TN earthing system
Width4 DIN modules
Formatmodular arrester with pluggable protection modules

Product details

A combined Type 1 and Type 2 arrester does two jobs in one set of modules: it takes the partial lightning current that a direct strike puts into an installation, and it limits the ordinary switching and induced surges that follow. This four-module DEHN unit does both for single-phase TN supplies.

Key features

  • Combined Type 1 and Type 2 duty in a single four-module arrester
  • Configured for single-phase TN systems with line and neutral protection
  • Fitted at the origin of the installation, upstream of the distribution boards
  • Modular construction allows individual protection modules to be replaced
  • Removes the need for separate Type 1 and Type 2 devices in a small board

Typical applications

Specify it at intake positions where partial lightning current is a credible risk: buildings with an external lightning protection system, properties fed by overhead lines, exposed rural and coastal sites, agricultural buildings, and single-phase industrial or telemetry supplies. A Type 2 device further downstream then handles the distribution boards themselves.

Compliance

Combined Type 1 and Type 2 devices are classified under the BS EN 61643-11 series and are installed at the origin of the installation. BS 7671 requires the risk from transient overvoltages to be assessed, with Type 1 protection used where partial lightning current may enter the installation and coordinated Type 2 protection downstream.