DEHN Combined Type 1+2 Surge Protection Device with Remote Signalling, 8 Module Three Phase TT/TN

Brand:
DEHN
Part number:
951315
EAN:
4013364126435

Eight-module combined lightning current and surge arrester for three-phase TT and TN systems, with monitoring contacts for remote end-of-life signalling.

  • Combined Type 1+2 protection
  • Three-phase TT and TN
  • Monitoring contacts for remote alarm
  • Eight DIN modules
£1,217.19 ex VAT£1,460.63 inc VAT

Out of stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

SupplyThree phase
Earthing systemTT, TN-S, TN-C-S (PME)
Earthing system (as supplied)TT/TN
Remote signalling contactYes
ApplicationMains AC

Protection

SPD typeType 1+2

Dimensions

DIN rail width8 modules

Construction

Replaceable protection moduleYes

Fit

MountingDIN rail

Identification

BrandDEHN
Part number951315
EAN4013364126435
RangeDEHNventil

More technical data

SPD classcombined Type 1 and Type 2
Configurationthree phase, TT/TN earthing systems
Status signallinglocal indication plus monitoring (remote signalling) contacts
Width8 DIN modules

Product details

An intake arrester that has reached the end of its life leaves the whole installation exposed, and on an industrial site nobody is opening the main panel to check. This eight-module combined Type 1 and 2 device for three-phase TT and TN systems adds monitoring contacts so the condition is reported.

Key features

  • Combined Type 1 and Type 2 protection for three-phase TT and TN installations
  • Monitoring contacts for remote signalling into BMS, SCADA or an alarm panel
  • Eight DIN modules covering three line poles plus the neutral path
  • Pluggable protection modules replaced individually, wiring left in place
  • Local status indication retained for inspection at the panel

Typical applications

Specify it for main intake panels on monitored industrial and infrastructure sites: manufacturing plants, distribution centres, water and wastewater works, data and telecoms facilities, and agricultural or renewable energy installations with an external lightning protection system. The contact feeds the site's existing alarm or SCADA reporting.

Compliance

Combined Type 1 and Type 2 devices are classified under the BS EN 61643-11 series and are installed at the origin of the installation, coordinated with Type 2 protection downstream. BS 7671 requires transient overvoltage risk to be assessed and appropriate protection provided.

Order today for fast UK dispatch, or contact us for the signalling contact ratings if you need them for a schedule.