Trade only · Free delivery over £100 ex VAT
Product image 1

DEHN DEHNvenCI DVCI 1 255 FM Type 1 Surge Protection Device with Integrated Backup Fuse

Brand:
DEHN
Part number:
961205
EAN:
4013364145115

Single-pole spark-gap Type 1 lightning current arrester with an integrated lightning-current-carrying backup fuse and a remote signalling changeover contact, in two DIN modules.

  • Type 1 lightning current arrester
  • Integrated backup fuse - no external fuse
  • Iimp 25kA, UP 1.5kV
  • Changeover contact for remote alarm
  • Two DIN modules
£522.41 ex VAT£626.89 inc VAT

Out of stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

SupplySingle phase
Remote signalling contactYes
ApplicationMains AC

Protection

SPD typeType 1+2
Lightning impulse current (Iimp per pole)25 kA
Voltage protection level (Up)1.5 kV

Dimensions

DIN rail width2 modules

Identification

BrandDEHN
Part number961205
EAN4013364145115
RangeDEHNvenCI

More technical data

ManufacturerDEHN (DEHNvenCI, type DVCI 1 255 FM)
SPD classType 1 / Class I to EN 61643-11 / IEC 61643-11
Nominal a.c. voltage (UN)230V, 50/60Hz; UC 255V
Lightning impulse current Iimp (10/350)25kA; specific energy 156.25 kJ/ohms
Nominal discharge current In (8/20)25kA; voltage protection level UP: 1.5kV
Follow current extinguishing capability Ifi50kArms; response time 100ns
Max mains-side overcurrent protectionnot required; internal backup fuse breaking capacity 100kA
Remote signallingchangeover contact, 250V/0.5A a.c.; width 2 modules, IP20

Product details

The usual headache with a Type 1 arrester at the intake is the separate backup fuse: it needs space, a fuse holder and correct selection. DEHNvenCI builds that fuse into the arrester. The DVCI 1 255 FM carries a 25kA lightning impulse current, needs no external mains-side overcurrent protection, and reports its own status through a changeover contact.

Key features

  • Integrated lightning-current-carrying backup fuse - no separate mains-side fuse required
  • Spark-gap technology with RADAX Flow follow current limitation for high system availability
  • Iimp of 25kA (10/350) with a voltage protection level held to 1.5kV
  • Remote signalling changeover contact rated 250V / 0.5A a.c.
  • Follow current limitation will not trip a 20A gG fuse up to 50kArms prospective

Typical applications

This is an origin-of-installation device: main intake positions and incoming panels in buildings with an external lightning protection system, or with an overhead supply, on sites where a direct strike can put partial lightning current into the installation. It suits industrial premises, agricultural buildings, telecoms and broadcast sites, and any switchboard where there is no room for a separate 315A backup fuse arrangement.

Compliance

Tested as a Type 1 / Class I device to EN 61643-11 and IEC 61643-11, with KEMA approval, a UL 94 V-0 enclosure and IP20 protection. Energy coordination is declared with Type 2 equipment and, within 10m, with Type 3 equipment. BS 7671 requires transient overvoltage risk to be assessed, with Type 1 protection used where partial lightning current may enter the installation.

Order today for fast UK dispatch on genuine DEHN lightning current arresters at trade-direct prices.