DEHN Type 1 Surge Protection Replacement Plug-In Module, Neutral (N) Three Phase
- Brand:
- DEHN
- Part number:
- 951100
- EAN:
- 4013364108448
Neutral (N) plug-in replacement protection module for DEHN combined Type 1 and 2 three-phase arresters on TT and TN systems. Restores the neutral-to-earth path.
- Neutral (N) plug-in spare module
- For DEHN three-phase Type 1+2 arresters
- TT/TN 3+1 configuration
- Restores the N-PE path
Out of stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Earthing system (as supplied) | TT/TN |
|---|---|
| Application | Mains AC |
Protection
| SPD type | Type 1+2 |
|---|
Fit
| Replaces | N (N-PE) |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 951100 |
| EAN | 4013364108448 |
| Range | DEHNventil |
| Part type | Replacement module / cartridge |
More technical data
| SPD class | combined Type 1 and Type 2 |
|---|---|
| Pole | neutral (N) |
| Configuration | three phase, TT/TN earthing system family |
| Format | plug-in replacement protection module |
Product details
Three-phase combined arresters on TT and TN-S systems use a 3+1 arrangement, and the single neutral module carries the spark gap from neutral to earth. This DEHN neutral (N) module is the replacement for that pole, plugging into the base part without any conductors being disturbed.
Key features
- Neutral (N) replacement module for DEHN three-phase combined Type 1 and 2 arresters
- Restores the N-PE spark gap in 3+1 TT and TN-S configurations
- Plug-in to the installed base part, so incoming terminations stay untouched
- Only the neutral pole is replaced; line modules remain in service
- Practical spare for industrial and infrastructure intake positions
Typical applications
Three-phase Type 1 protection is fitted at intake positions in industrial premises, agricultural buildings, water and wastewater sites, telecom compounds and any structure with an external lightning protection system. On these sites the neutral module takes a heavy share of the partial lightning current, so it is the module most worth holding as a spare.
Compliance
Combined Type 1 and Type 2 devices are classified under the BS EN 61643-11 series. Line and neutral modules are not interchangeable - fit only the neutral module specified for your arrester base.
Order today for fast UK dispatch, or send us the arrester type reference and we will confirm the correct module.