Trade only · Free delivery over £100 ex VAT
Product image 1

DEHN Type 1 Surge Protection Replacement Plug-In Module, Neutral (N) Three Phase

Brand:
DEHN
Part number:
951100
EAN:
4013364108448

Neutral (N) plug-in replacement protection module for DEHN combined Type 1 and 2 three-phase arresters on TT and TN systems. Restores the neutral-to-earth path.

  • Neutral (N) plug-in spare module
  • For DEHN three-phase Type 1+2 arresters
  • TT/TN 3+1 configuration
  • Restores the N-PE path
£384.90 ex VAT£461.88 inc VAT

Out of stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

Earthing system (as supplied)TT/TN
ApplicationMains AC

Protection

SPD typeType 1+2

Fit

ReplacesN (N-PE)

Identification

BrandDEHN
Part number951100
EAN4013364108448
RangeDEHNventil
Part typeReplacement module / cartridge

More technical data

SPD classcombined Type 1 and Type 2
Poleneutral (N)
Configurationthree phase, TT/TN earthing system family
Formatplug-in replacement protection module

Product details

Three-phase combined arresters on TT and TN-S systems use a 3+1 arrangement, and the single neutral module carries the spark gap from neutral to earth. This DEHN neutral (N) module is the replacement for that pole, plugging into the base part without any conductors being disturbed.

Key features

  • Neutral (N) replacement module for DEHN three-phase combined Type 1 and 2 arresters
  • Restores the N-PE spark gap in 3+1 TT and TN-S configurations
  • Plug-in to the installed base part, so incoming terminations stay untouched
  • Only the neutral pole is replaced; line modules remain in service
  • Practical spare for industrial and infrastructure intake positions

Typical applications

Three-phase Type 1 protection is fitted at intake positions in industrial premises, agricultural buildings, water and wastewater sites, telecom compounds and any structure with an external lightning protection system. On these sites the neutral module takes a heavy share of the partial lightning current, so it is the module most worth holding as a spare.

Compliance

Combined Type 1 and Type 2 devices are classified under the BS EN 61643-11 series. Line and neutral modules are not interchangeable - fit only the neutral module specified for your arrester base.

Order today for fast UK dispatch, or send us the arrester type reference and we will confirm the correct module.