Trade only · Free delivery over £100 ex VAT
Product image 1

DEHN Type 1 Surge Protection Replacement Plug-In Module, Line (L) Single Phase

Brand:
DEHN
Part number:
951001
EAN:
4013364128422

Line (L) plug-in replacement protection module for DEHN combined Type 1 and 2 arresters on single-phase TN systems. Restores the line pole without disturbing the base part.

  • Line (L) plug-in spare module
  • For DEHN combined Type 1+2 arresters
  • Single-phase TN configuration
  • No re-termination of the base part
£308.68 ex VAT£370.42 inc VAT

Out of stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

Earthing system (as supplied)TN
ApplicationMains AC

Protection

SPD typeType 1+2

Fit

ReplacesL

Identification

BrandDEHN
Part number951001
EAN4013364128422
RangeDEHNventil
Part typeReplacement module / cartridge

More technical data

SPD classcombined Type 1 and Type 2
Poleline (L)
Configurationsingle phase, TN earthing system family
Formatplug-in replacement protection module

Product details

A combined lightning current and surge arrester at the intake is an expensive item to replace wholesale, and it does not need to be. This DEHN line (L) protection module plugs into the installed base part and restores the line pole of a single-phase Type 1 and 2 arrester to full duty.

Key features

  • Line (L) replacement module for DEHN combined Type 1 and 2 arresters
  • Plug-in fit to the existing base part - incoming tails stay terminated
  • Restores the spark-gap line path after an end-of-life indication
  • Individual pole replacement rather than changing the whole arrester
  • Sensible spare where the arrester protects an origin-of-installation position

Typical applications

Type 1 arresters sit at intake positions on buildings with lightning protection systems, overhead supplies and exposed rural or industrial sites, so a failure there leaves the whole installation without its first line of defence. Holding the line module as a spare lets facilities and maintenance teams clear a red indication at the next available shutdown rather than waiting on a lead time.

Compliance

Combined Type 1 and Type 2 devices are classified under the BS EN 61643-11 series. Replacement modules must match the base part and the system voltage the arrester was supplied for - fit only the module specified for your device.

Order today for fast UK dispatch, or send us the arrester type reference and we will confirm the correct module.