DEHN Type 1 Surge Protection Replacement Plug-In Module, Neutral (N) Single Phase
- Brand:
- DEHN
- Part number:
- 951050
Neutral (N) plug-in replacement protection module for DEHN combined Type 1 and 2 arresters on single-phase TT and TN systems. Restores the neutral-to-earth path.
- Neutral (N) plug-in spare module
- For DEHN combined Type 1+2 arresters
- Single-phase TT/TN configuration
- Restores the N-PE path
Out of stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Earthing system (as supplied) | TT/TN |
|---|---|
| Application | Mains AC |
Protection
| SPD type | Type 1+2 |
|---|
Fit
| Replaces | N (N-PE) |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 951050 |
| Range | DEHNventil |
| Part type | Replacement module / cartridge |
More technical data
| SPD class | combined Type 1 and Type 2 |
|---|---|
| Pole | neutral (N) |
| Configuration | single phase, TT/TN earthing system family |
| Format | plug-in replacement protection module |
Product details
In a single-phase TT or TN arrester the neutral module carries the spark gap that bridges neutral to earth, and it is a different component from the line module beside it. This DEHN neutral (N) replacement plugs into the existing base part and puts that path back into service.
Key features
- Neutral (N) replacement module for DEHN combined Type 1 and 2 arresters
- Restores the N-PE spark gap path used in TT and TN-S configurations
- Plug-in fit to the installed base part with no re-termination required
- Replaces only the affected pole, leaving healthy line modules in place
- Worth stocking on electrode-earthed sites with origin-position protection
Typical applications
Single-phase TT installations with Type 1 protection are typically rural properties, pumping and telemetry stations, masts and outbuildings fed from an overhead supply. The neutral module on these arresters takes the full partial lightning current from the N-PE path, so having the correct spare available keeps a site protected without a second visit.
Compliance
Combined Type 1 and Type 2 devices are classified under the BS EN 61643-11 series. Fit only the neutral module specified for your arrester base - line and neutral modules are not interchangeable.
Order today for fast UK dispatch, or send us the arrester reference and we will confirm the right module.