Products
Terasaki · 331701
40 A · 3 pole · 250 A · 36 kA
Subtotal (1 unit)£432.50/unit
£432.50 ex VAT£519.00 inc VAT
Checking stock...
Terasaki · 332005
40 A · 3 pole · 250 A · 65 kA
Subtotal (1 unit)£465.14/unit
£465.14 ex VAT£558.17 inc VAT
Checking stock...
Terasaki · 331800
125 A · 3 pole · 250 A · 36 kA
Subtotal (1 unit)£432.50/unit
£432.50 ex VAT£519.00 inc VAT
Checking stock...
Terasaki · 332104
125 A · 3 pole · 250 A · 65 kA
Subtotal (1 unit)£465.14/unit
£465.14 ex VAT£558.17 inc VAT
Checking stock...
Terasaki · 337802
160 A · 3 pole · 250 A · 36 kA
Subtotal (1 unit)£620.18/unit
£620.18 ex VAT£744.22 inc VAT
Checking stock...
Terasaki · 337925
160 A · 3 pole · 250 A · 65 kA
Subtotal (1 unit)£644.67/unit
£644.67 ex VAT£773.60 inc VAT
Checking stock...
Terasaki · 331909
250 A · 3 pole · 250 A · 36 kA
Subtotal (1 unit)£860.09/unit
£860.09 ex VAT£1,032.11 inc VAT
Checking stock...
Terasaki · 332203
250 A · 3 pole · 250 A · 65 kA
Subtotal (1 unit)£922.11/unit
£922.11 ex VAT£1,106.53 inc VAT
Checking stock...
Terasaki · 379604
250 A · 3 pole · 400 A · 50 kA
Subtotal (1 unit)£1,101.79/unit
£1,101.79 ex VAT£1,322.15 inc VAT
Checking stock...
Terasaki · 379628
400 A · 3 pole · 400 A · 50 kA
Subtotal (1 unit)£1,101.79/unit
£1,101.79 ex VAT£1,322.15 inc VAT
Checking stock...
Terasaki · 812262
630 A · 3 pole · 800 A · 50 kA
Subtotal (1 unit)£1,966.78/unit
£1,966.78 ex VAT£2,360.14 inc VAT
Checking stock...
Terasaki · 812309
630 A · 4 pole · 800 A · 50 kA
Subtotal (1 unit)£2,580.86/unit
£2,580.86 ex VAT£3,097.03 inc VAT
Checking stock...
Terasaki · 553240
800 A · 3 pole · 1250 A · 50 kA
Subtotal (1 unit)£2,899.75/unit
£2,899.75 ex VAT£3,479.70 inc VAT
Checking stock...
Terasaki · 553400
800 A · 4 pole · 1250 A · 50 kA
Subtotal (1 unit)£4,017.64/unit
£4,017.64 ex VAT£4,821.17 inc VAT
Checking stock...
Showing 14 of 14
Buying guide
An electronic MCCB replaces the bimetal and magnetic elements of a thermal-magnetic breaker with a current-sensing trip unit whose settings are adjusted on the front of the device. That makes it the choice where discrimination between a main board and its sub-boards matters, where the circuit rating sits between the fixed ratings, or where the protection has to be documented to a setting.
Terasaki's TemBreak 2 electronic types in the shop run from the 250 A frame S250-NE (36 kA) and S250-GE (65 kA) through the 400 A frame S400-NE to the 800 A frame S800-NE and the 1250 A frame S1250-SE incomers. Filter by rated current and breaking capacity; each page carries the series datasheet.
Questions
- What does an electronic trip unit add?
- Adjustable long-time (overload), short-time and instantaneous settings, so the breaker can be graded closely with the devices above and below it and set to the circuit rather than only to the nearest rating.
- Do these fit a Resilience board?
- The 250 AF electronic types fit the hybrid and Form 3b Resilience Plus boards as outgoing ways; the 400 AF type fits the twin 400 AF board; the 800 AF and 1250 AF types are incomers for the Plus incomer housings.
- Is a neutral CT needed?
- On a 3 pole electronic MCCB protecting a circuit with a neutral, the manufacturer's guidance on an external neutral CT applies; ask us with the application details.