DEHN Type 3 Surge Protection Device with Remote Signalling, 2 Module Three Phase 25A

Brand:
DEHN
Part number:
953405
EAN:
4013364115774

Three-phase Type 3 surge arrester for 25A loads in two DIN modules, with monitoring contacts so an expired protection module can be alarmed remotely.

  • Type 3 point-of-use protection
  • Three phase, 25A load rating
  • Monitoring contacts for remote alarm
  • Two DIN modules
£205.12 ex VAT£246.14 inc VAT

10 in stock

Datasheet (PDF)Opens in a new tab

UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.

Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.

Project quantities or a lead time to check? Request a quote

Specifications

Electrical

Rated current25 A
SupplyThree phase
Earthing systemTT, TN-S, TN-C-S (PME)
Earthing system (as supplied)All earthing systems
Remote signalling contactYes
ApplicationMains AC

Protection

SPD typeType 3

Dimensions

DIN rail width2 modules

Construction

Replaceable protection moduleYes

Fit

MountingDIN rail

Identification

BrandDEHN
Part number953405
EAN4013364115774
RangeDEHNrail

More technical data

SPD classType 3 (point-of-use)
Configurationthree phase, 25A
Status signallinglocal indication plus monitoring (remote signalling) contacts
Width2 DIN modules

Product details

Point-of-use protection for three-phase plant, with the addition of monitoring contacts. This two-module DEHN Type 3 arrester protects 25A three-phase circuits and can report its own end of life to a control system, which is the difference between knowing your protection is live and assuming it is.

Key features

  • Type 3 fine protection for three-phase circuits rated up to 25A
  • Monitoring contacts for remote signalling into a BMS, PLC or alarm panel
  • Two DIN modules, mounting alongside the rest of the machine panel switchgear
  • Local indication retained for visual checks during maintenance
  • Supports planned module replacement instead of reactive fault finding

Typical applications

Fit it in process and production panels where an unnoticed failure carries a real cost: bottling and packaging lines, cold stores and refrigeration packs, water and effluent pumping, air handling plant, and any unattended three-phase machine monitored from a SCADA or BMS head-end. The signalling contact commonly goes to a spare input already available on the panel controller.

Compliance

Type 3 protection is the fine-protection class in the BS EN 61643-11 series and is coordinated with the Type 2 device upstream. BS 7671 requires transient overvoltage risk to be assessed and surge protection provided where the consequences justify it.