DEHN Type 3 Surge Protection Device with Remote Signalling, 1 Module Single Phase 25A
- Brand:
- DEHN
- Part number:
- 953205
- EAN:
- 4013364108318
Single-phase Type 3 surge arrester for a 25A load in a single DIN module, fitted with monitoring contacts so end of life can be signalled back to a BMS or panel indicator.
- Type 3 point-of-use protection
- Single phase, 25A, one DIN module
- Monitoring contacts for remote alarm
- Plug-in protection module
Out of stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Rated current | 25 A |
|---|---|
| Supply | Single phase |
| Earthing system | TT, TN-S, TN-C-S (PME) |
| Earthing system (as supplied) | All earthing systems |
| Remote signalling contact | Yes |
| Application | Mains AC |
Protection
| SPD type | Type 3 |
|---|
Dimensions
| DIN rail width | 1 module |
|---|
Construction
| Replaceable protection module | Yes |
|---|
Fit
| Mounting | DIN rail |
|---|
Identification
| Brand | DEHN |
|---|---|
| Part number | 953205 |
| EAN | 4013364108318 |
| Range | DEHNrail |
More technical data
| SPD class | Type 3 (point-of-use) |
|---|---|
| Configuration | single phase, 25A |
| Status signalling | local indication plus monitoring (remote signalling) contacts |
| Width | 1 DIN module |
Product details
This is the remote-signalling version of DEHN's single-module Type 3 arrester for 25A single-phase circuits. Alongside the local status window it carries a set of monitoring contacts, so a module that has reached the end of its life announces itself to your control system instead of waiting to be found on a visual inspection.
Key features
- Type 3 point-of-use protection in a single DIN module for 25A single-phase circuits
- Monitoring contacts allow end-of-life status to be wired to a BMS, PLC or panel lamp
- Plug-in protection module design keeps replacement clear of the field wiring
- Local status indication remains available for on-site inspection
- Suits unattended and remote sites where nobody checks the board regularly
Typical applications
Remote signalling earns its keep wherever the board is not looked at often: unmanned plant rooms, pumping and treatment stations, telecoms cabinets, roadside and car park equipment, remote CCTV and ANPR posts, and distributed retail estates monitored from one head office. Wiring the contact into an existing alarm input turns surge protection into something you can report on rather than something you hope is still working.
Compliance
Type 3 devices are the fine-protection class within the BS EN 61643-11 series and are installed downstream of, and coordinated with, Type 2 protection. BS 7671 requires transient overvoltage risk to be assessed and protection provided where the consequences justify it.
Order today for fast UK dispatch, or ask us for the datasheet figures if you need them for a design submission.