Trade only · Free delivery over £100 ex VAT

Form 3b Panel Boards

Boards whose outgoing terminals are separated from the busbars by rigid barriers, as well as from each other.

Skip to products

14 productsshowing 1-14

Products

Resilience Standard 250A 4-Way MCCB Panelboard, Form 3b Type 2

Terasaki · TRS25004TM125

250 A · 4-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic

£1,342.48 ex VAT£1,610.98 inc VAT

Checking stock...

Resilience Standard 250A 6-Way MCCB Panelboard, Form 3b Type 2

Terasaki · TRS25006TM125

250 A · 6-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic

£1,443.44 ex VAT£1,732.13 inc VAT

Checking stock...

Resilience Standard 250A 8-Way MCCB Panelboard, Form 3b Type 2

Terasaki · TRS25008TM125

250 A · 8-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic

£1,728.27 ex VAT£2,073.92 inc VAT

Checking stock...

Resilience Standard 250A 12-Way MCCB Panelboard, Form 3b Type 2

Terasaki · TRS25012TM125

250 A · 12-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic

£1,907.41 ex VAT£2,288.89 inc VAT

Checking stock...

Resilience Plus 400A 6-Way Panelboard, Form 3b Type 2, Electronic Option

Terasaki · TRP40006ELE2250

400 A · 6-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic or electronic

£1,866.38 ex VAT£2,239.66 inc VAT

Checking stock...

Resilience Plus 400A 12-Way Panelboard, Form 3b Type 2, Electronic Option

Terasaki · TRP40012ELE2250

400 A · 12-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic or electronic

£2,684.79 ex VAT£3,221.75 inc VAT

Checking stock...

Resilience Plus 400A 18-Way Panelboard, Form 3b Type 2, Electronic Option

Terasaki · TRP40018ELE2250

400 A · 18-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic or electronic

£3,644.64 ex VAT£4,373.57 inc VAT

Checking stock...

Resilience Standard 400A 6-Way MCCB Panelboard, Form 3b Type 2

Terasaki · TRS40006TM125

400 A · 6-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic

£1,514.99 ex VAT£1,817.99 inc VAT

Checking stock...

Resilience Standard 400A 8-Way MCCB Panelboard, Form 3b Type 2

Terasaki · TRS40008TM125

400 A · 8-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic

£1,790.43 ex VAT£2,148.52 inc VAT

Checking stock...

Resilience Standard 400A 12-Way MCCB Panelboard, Form 3b Type 2

Terasaki · TRS40012TM125

400 A · 12-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic

£2,065.89 ex VAT£2,479.07 inc VAT

Checking stock...

Resilience Standard 400A 18-Way MCCB Panelboard, Form 3b Type 2

Terasaki · TRS40018TM125

400 A · 18-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic

£2,754.51 ex VAT£3,305.41 inc VAT

Checking stock...

Resilience Plus 800A 6-Way Panelboard, Form 3b Type 2, Electronic Option

Terasaki · TRP80006ELE2250

800 A · 6-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic or electronic

£2,523.90 ex VAT£3,028.68 inc VAT

Checking stock...

Resilience Plus 800A 12-Way Panelboard, Form 3b Type 2, Electronic Option

Terasaki · TRP80012ELE2250

800 A · 12-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic or electronic

£3,443.17 ex VAT£4,131.80 inc VAT

Checking stock...

Resilience Plus 800A 18-Way Panelboard, Form 3b Type 2, Electronic Option

Terasaki · TRP80018ELE2250

800 A · 18-way · Form: Form 3b Type 2 · Outgoing: Thermal-magnetic or electronic

£4,699.01 ex VAT£5,638.81 inc VAT

Checking stock...

Showing 14 of 14

Buying guide

The forms of separation in BS EN 61439-2 describe how far the inside of a switchboard is divided into compartments. Form 3b Type 2 goes one step beyond Form 3a: the outgoing cable terminals are separated from the busbars by rigid barriers, so a circuit can be terminated or isolated with less of the live board exposed.

Every Terasaki Resilience Standard board is Form 3b Type 2 as supplied. On Resilience Plus, the Form 3b Type 2 boards are the hybrid versions that accept thermal-magnetic or electronic outgoing MCCBs, in 400 A and 800 A, with 6, 12 or 18 ways.

Questions

What does Form 3b Type 2 mean?
Form 3 separates the busbars from the functional units and the units from each other. Form 3b also separates the terminals for the outgoing cables from the busbars; Type 2 does that with rigid metallic or non-metallic barriers rather than insulated coverings.
When is Form 3b specified?
Where a consultant or the client wants an outgoing terminal to be worked on with the board live, with the busbars shielded. Many specifications for commercial buildings call for Form 3b Type 2 or better on sub-main boards.
Which Resilience boards are Form 3a?
The Resilience Plus boards without the Form 3b suffix: the thermal-magnetic and hybrid 400 A and 800 A boards and the twin 400 AF board.