Europa FS633PSNME 63A 3-Pole + Switched Neutral Door-Interlocked Fused Switch, Steel Enclosure
- Brand:
- Europa Components
- Part number:
- FS633PSNME
- EAN:
- 5056551206014
Europa FS633PSNME 63 A three-pole and switched-neutral enclosed fused switch with a door-interlocked steel enclosure and gG/gL fuse carriers. Local isolation and overcurrent protection for a machine or sub-circuit.
- 63 A, 3-pole + switched neutral
- gG/gL fuse carriers to EN 60269
- Door-interlocked steel enclosure
- 690 V rated, 6 kV impulse withstand
- 30 kA rated fused short-circuit current
20 in stock
UK delivery £9.95 ex VAT, free on orders of £100 ex VAT or more; usually 2-3 working days.
Minimum order £50 ex VAT. All prices exclude VAT, which is added at checkout.
Project quantities or a lead time to check? Request a quote
Specifications
Electrical
| Rated current | 63 A |
|---|---|
| Poles / neutral | 3 pole + switched neutralWhat does this mean?Three phase poles plus a dedicated neutral pole, all worked by the one handle, so the neutral is isolated together with the phases. |
| Supply | Three phase |
| Utilisation category | AC-22 |
| Current at AC-22 | 63 A |
| Fuse type | gG/gL (EN 60269) |
Protection
| Door interlock | Yes |
|---|---|
| IP rating | IP65 |
Construction
| Enclosure material | Sheet steel |
|---|
Fit
| Mounting | Surface / wall |
|---|
Identification
| Brand | Europa Components |
|---|---|
| Part number | FS633PSNME |
| EAN | 5056551206014 |
| Range | Europa FS |
| Type | Switch fuse |
More technical data
| Utilisation | AC-22 at 400 V (415 V) |
|---|---|
| Rated operational voltage Ue | 690 V |
| Rated impulse withstand voltage Uimp | 6 kV |
| Rated fused short-circuit current | 30 kA |
| Fuse links | gG/gL type to EN 60269-1 / HD 60269-2 |
| Enclosure | steel, door-interlocked |
Product details
The Europa FS633PSNME puts a 63 A load-break switch and its fuse protection in one steel enclosure. Three poles plus a switched neutral are broken together, and the door interlock keeps the fuse carriers out of reach while the switch is closed.
Key features
- 63 A rated, three-pole with a switched neutral so all four conductors are broken
- Integral fuse carriers for gG/gL fuse links to EN 60269 - short-circuit and overload protection without a separate fuse unit
- Door interlock prevents the enclosure being opened with the switch in the ON position
- 30 kA rated fused short-circuit current, so it can be used where prospective fault current is high
- Rated to 690 V, giving headroom on 400/415 V three-phase systems
- Steel enclosure for robust wall mounting in industrial environments
Typical applications
Typical positions are beside a motor starter, on the wall of a plant room, at the edge of a production cell, or on the supply to a farm building or workshop. The switched neutral means all four conductors are broken, which matters when the circuit is being worked on or tested, and the fuses give the circuit short-circuit protection without a separate fuse unit.
Compliance
The switch is built to IEC and EN 60947-3 for low-voltage switch-disconnectors, and the fuse holders to EN 60269-1 / HD 60269-2. Rated at 690 V with a 6 kV impulse withstand and a 30 kA rated fused short-circuit current, it suits 400/415 V industrial systems.